Chapter 46 Configuring Online Diagnostics

Configuring Online Diagnostics

This example shows how to schedule diagnostic testing to occur weekly at a specific time on member switch 6 when this command is entered on a Catalyst 3750-E stack master:

Switch(config)# diagnostic schedule switch 6 test 1-4,7 weekly saturday 10:30

For more examples, see the “Examples” section of the diagnostic schedule command in the command reference for this release.

Configuring Health-Monitoring Diagnostics

You can configure health-monitoring diagnostic testing on a switch while it is connected to a live network. You can configure the execution interval for each health-monitoring test, enable the switch to generate a syslog message because of a test failure, and enable a specific test.

By default, health monitoring is disabled, but the switch generates a syslog message when a test fails.

Beginning in privileged EXEC mode, follow these steps to configure and enable the health-monitoring diagnostic tests:

 

Command

Purpose

Step 1

 

 

configure terminal

Enter global configuration mode.

Step 2

 

 

diagnostic monitor interval switch

Configure the health-monitoring interval of the specified tests.

 

number test {name test-id

The switch number keyword is supported only on Catalyst 3750-E

 

test-id-range all} hh:mm:ss

 

switches. The range is from 1 to 9.

 

milliseconds day

 

When specifying the tests, use one of these parameters:

 

 

 

 

name—Name of the test that appears in the show diagnostic content

 

 

command output.

 

 

test-id—ID number of the test that appears in the show diagnostic

 

 

content command output.

 

 

test-id-range—ID numbers of the tests that appear in the show

 

 

diagnostic content command output.

 

 

all—All of the diagnostic tests.

 

 

When specifying the interval, set these parameters:

 

 

hh:mm:ss—Monitoring interval in hours, minutes, and seconds. The

 

 

range for hh is 0 to 24, and the range for mm and ss is 0 to 60.

 

 

milliseconds—Monitoring interval in milliseconds (ms). The range is

 

 

from 0 to 999.

 

 

day—Monitoring interval in the number of days. The range is from 0

 

 

to 20.

Step 3

 

 

diagnostic monitor syslog

(Optional) Configure the switch to generate a syslog message when a

 

 

health-monitoring test fails.

 

 

 

Catalyst 3750-E and 3560-E Switch Software Configuration Guide

 