Chapter 33 Configuring SNMP

Configuring SNMP

Note Though visible in the command-line help strings, the cpu [threshold] keyword is not supported on the Catalyst 3750-E switch. Though visible in the command-line help strings, the cpu [threshold], fru-ctrl, insertion, and removal keywords are not supported on the Catalyst 3560-E switch. To enable the sending of SNMP inform notifications, use the snmp-server enable traps global configuration command combined with the snmp-server host host-addrinforms global configuration command.

You can use the snmp-server host global configuration command to a specific host to receive the notification types listed in Table 33-5.

Beginning in privileged EXEC mode, follow these steps to configure the switch to send traps or informs to a host:

 

Command

Purpose

Step 1

 

 

configure terminal

Enter global configuration mode.

Step 2

 

 

snmp-server engineID remote

Specify the engine ID for the remote host.

 

ip-address engineid-string

 

Step 3

 

 

snmp-server user username

Configure an SNMP user to be associated with the remote host created in

 

groupname {remote host [udp-port

Step 2.

 

port]} {v1 [access access-list] v2c

Note You cannot configure a remote user for an address without first

 

[access access-list] v3 [encrypted]

 

configuring the engine ID for the remote host. Otherwise, you

 

[access access-list] [auth {md5 sha}

 

receive an error message, and the command is not executed.

 

auth-password]}

 

 

Step 4

 

 

snmp-server group groupname {v1

Configure an SNMP group.

 

v2c v3 {auth noauth priv}} [read

 

 

readview] [write writeview] [notify

 

 

notifyview] [access access-list]

 

Step 5

 

 

snmp-server host host-addr

Specify the recipient of an SNMP trap operation.

 

[informs traps] [version {1 2c 3

For host-addr,specify the name or Internet address of the host (the

 

{auth noauth priv}}]

 

targeted recipient).

 

community-string [notification-type]

 

(Optional) Enter informs to send SNMP informs to the host.

 

 

 

 

(Optional) Enter traps (the default) to send SNMP traps to the host.

 

 

(Optional) Specify the SNMP version (1, 2c, or 3). SNMPv1 does

 

 

not support informs.

 

 

(Optional) For Version 3, select authentication level auth, noauth, or

 

 

priv.

 

 

Note The priv keyword is available only when the cryptographic

 

 

universal software image is installed.

 

 

For community-string, when version 1 or version 2c is specified,

 

 

enter the password-like community string sent with the notification

 

 

operation. When version 3 is specified, enter the SNMPv3 username.

 

 

(Optional) For notification-type, use the keywords listed in

 

 

Table 33-5 on page 33-12. If no type is specified, all notifications are

 

 

sent.

 

 

 

 

Catalyst 3750-E and 3560-E Switch Software Configuration Guide