Chapter 32 Configuring System Message Logging

Configuring System Message Logging

Beginning in privileged EXEC mode, follow these steps to configure synchronous logging. This procedure is optional.

 

Command

Purpose

Step 1

 

 

configure terminal

Enter global configuration mode.

Step 2

 

 

line [console vty] line-number

Specify the line to be configured for synchronous logging of

 

[ending-line-number]

messages.

 

 

• Use the console keyword for configurations that occur through

 

 

the switch console port or the Ethernet management port.

 

 

• Use the line vty line-numbercommand to specify which vty

 

 

lines are to have synchronous logging enabled. You use a vty

 

 

connection for configurations that occur through a Telnet

 

 

session. The range of line numbers is from 0 to 15.

 

 

You can change the setting of all 16 vty lines at once by entering:

 

 

line vty 0 15

 

 

Or you can change the setting of the single vty line being used for

 

 

your current connection. For example, to change the setting for vty

 

 

line 2, enter:

 

 

line vty 2

 

 

When you enter this command, the mode changes to line

 

 

configuration.

Step 3

 

 

logging synchronous [level [severity-level

Enable synchronous logging of messages.

 

all] limit number-of-buffers]

• (Optional) For level severity-level, specify the message severity

 

 

 

 

level. Messages with a severity level equal to or higher than this

 

 

value are printed asynchronously. Low numbers mean greater

 

 

severity and high numbers mean lesser severity. The default is 2.

 

 

• (Optional) Specifying level all means that all messages are

 

 

printed asynchronously regardless of the severity level.

 

 

• (Optional) For limit number-of-buffers, specify the number of

 

 

buffers to be queued for the terminal after which new messages

 

 

are dropped. The range is 0 to 2147483647. The default is 20.

Step 4

 

 

end

Return to privileged EXEC mode.

Step 5

 

 

show running-config

Verify your entries.

Step 6

 

 

copy running-config startup-config

(Optional) Save your entries in the configuration file.

 

 

 

To disable synchronization of unsolicited messages and debug output, use the no logging synchronous [level severity-level all] [limit number-of-buffers] line configuration command.

Catalyst 3750-E and 3560-E Switch Software Configuration Guide

 