Chapter 46 Configuring Online Diagnostics

Configuring Online Diagnostics

 

Command

Purpose

Step 4

 

 

diagnostic monitor threshold switch

(Optional) Set the failure threshold for the health-monitoring tests.

 

number test {name test-id

The switch number keyword is supported only on Catalyst 3750-E

 

test-id-range all} failure count count

 

switches. The range is from 1 to 9.

 

 

 

 

When specifying the tests, use one of these parameters:

 

 

name—Name of the test that appears in the show diagnostic content

 

 

command output.

 

 

test-id—ID number of the test that appears in the show diagnostic

 

 

content command output.

 

 

test-id-range—ID numbers of the tests that appear in the show

 

 

diagnostic content command output.

 

 

all—All of the diagnostic tests.

 

 

The range for the failure threshold count is 0 to 99.

 

 

 

Step 5 diagnostic monitor switch number test

Enable the specified health-monitoring tests.

 

{name test-id test-id-range all}

The switch number keyword is supported only on Catalyst 3750-E

 

 

 

 

switches. The range is from 1 to 9.

 

 

When specifying the tests, use one of these parameters:

 

 

name—Name of the test that appears in the show diagnostic content

 

 

command output.

 

 

test-id—ID number of the test that appears in the show diagnostic

 

 

content command output.

 

 

test-id-range—ID numbers of the tests that appear in the show

 

 

diagnostic content command output.

 

 

all—All of the diagnostic tests.

Step 6

 

 

end

Return to privileged EXEC mode.

 

 

 

Step 7 show diagnostic {content post result

Display the online diagnostic test results and the supported test suites. See

 

schedule status switch}

the “Displaying Online Diagnostic Tests and Test Results” section on

 

 

page 46-6for more information.

Step 8

 

 

show running-config

Verify your entries.

Step 9

 

 

copy running-config startup-config

(Optional) Save your entries in the configuration file.

 

 

 

To disable diagnostic testing and return to the default settings, use these commands:

Note The switch number option is supported only on Catalyst 3750-E switches.

To disable online diagnostic testing, use the no diagnostic monitor switch number test {name test-id test-id-range all} global configuration command.

To return to the default health-monitoring interval, use the no diagnostic monitor interval switch number test {name test-id test-id-range all} global configuration command.

Catalyst 3750-E and 3560-E Switch Software Configuration Guide

46-4

OL-9775-02

 

 

Page 1124
Image 1124
Cisco Systems 3750E Diagnostic monitor threshold switch, Diagnostic monitor switch number test, Schedule status switch