Indicator Icon Description
The power/status indicator flashes amber indicating the following conditions (continued):
•PSU module reading exceed threshold limits
•Power > 1480 W
•Voltage > 14.5 V
•Voltage < 10.75 V
•Current > 13 A
•Temperature > 60 °C
•Fan speed < 500 rpm
•PSU module status (from PSU STATUS_WORD)
•PSU module OVP
•PSU module OCP
•PSU module OTP
•PSU module fan fault protection (FFP)
•PSU module input over current
•PSU module input over power
•PSU module AC loss
•PSU module works in boot mode
•Communication error
NOTE: When connected to a power source, main power is automatically distributed to the PowerEdge C8000 server enclosure. After the server enclosure is powered up the power/event indicator on the front of the enclosure will light up green and main power is applied to all sleds in the enclosure.
4Turn on the sleds in the server enclosure.
To turn on the C8220 or C8220X compute sled, press the power button on each sled, or power on the sled using the baseboard management controller. When power is applied to the sled, the
Rack Mount Configuration