Rack Mount Configuration 249
NOTE: When connected to a power source, main power is automatically
distributed to the PowerEdge C8000 server enclosure. After the server enclosure is
powered up the power/event indicator on the front of the enclosure will light up
green and main power is applied to all sleds in the enclosure.
4
Turn on the sleds in the server enclosure.
To turn on the C8220 or C8220X compute sled, press the power button on
each sled, or power on the sled using the baseboard management
controller. When power is applied to the sled, the power-on indicator on
front of the sled will light up green. When installed into the server
enclosure, the C8000XD storage sled automatically powers on.
The power/status indicator flashes amber indicating
the following conditions (continued):
• PSU modu le reading exceed thre shold limits
•Power > 1480 W
•Voltage > 14.5 V
•Voltage < 10.75 V
•Current > 13 A
•Temperature > 60 °C
•Fan speed < 500 rpm
• PSU module status (from PSU STATUS_WORD)
•PSU module OVP
•PSU module OCP
•PSU module OTP
•PSU module fan fault protection (FFP)
•PSU module input o ver current
•PSU module input over power
•PSU module AC loss
•PSU module works in boot mode
•Communication erro r
Indicator Icon Description