PMC Configuration Information
The PMC configuration information is stored in the PMC board's internal EEPROM. You must use TFTP server to retrieve the configuration data and then use Notepad or a text editor to view or change the configuration data.
For example, a configuration data should have the following information:
CONNECT.TYPE=STATIC/DHCP
IP=192.168.0.120
NETMASK=255.255.255.0
GATEWAY=192.168.0.1
TRAP.DESTINATION1=0.0.0.0
TRAP.DESTINATION2=0.0.0.0
TRAP.DESTINATION3=0.0.0.0
TRAP.DESTINATION4=0.0.0.0
TRAP.DESTINATION5=0.0.0.0
SNMP.RD.COMMUNITY.STR=public
SNMP.RW.COMMUNITY.STR=private
MANAGE.ACSOCKET.A.DEFAULT.POWER=ON/OFF
MANAGE.ACSOCKET.B.DEFAULT.POWER=ON/OFF
MANAGE.ACSOCKET.C.DEFAULT.POWER=ON/OFF
MANAGE.PDU.DEFAULT.POWER=ON/OFF
MANAGE.PSU.CONFIGURATION=5+1
By default, the PMC controller uses DHCP to acquire an IP address. The system MUST follow the same DHCP retry mechanism that exists in the BMCs (any parameter needed for this MUST be stored in the configuration file). DHCP client MUST retry forever.