Using the System Setup Program 71
5
In the Remote Access Configuration screen, verify the following settings:
Remote Access: Enabled
Serial port number: COM2 as SOL
Serial Port Mode: 115200 8, n,1
Flow Control: None
Redirection After BIOS POST: Always
•Terminal Type: ANSI
See "Remote Access Configuration" on page 113 for details. Make sure the
host and client are on the same network.
6
Press <Esc> to return to the System Setup screen. Press <Esc> again,
and a message prompts you to save the changes.
Enabling and Configuring Console Redirection Via BMC SOL
When using the BMC management port, you have two options for
connecting and managing servers: Dedicated-NIC mode and Shared-NIC
mode. The following procedures show the setup option of the BMC
management port through a Dedicated-NIC or Shared-NIC.
To activate console redirection via a dedicated BMC management port, you
must configure the following settings:
1
Connect the sled system board and node power distribution board with a
BMC cable.
2
Connect the network cable to the BMC management port. See
"Compute
Sleds" on page26 for the location of the BMC management port on the
sled.
3
Press <F2> immediately after a power-on or reboot to enter System
Setup.
4
In the System Setup screen, select the
Server
menu and press <Enter>.
5
In the Server screen, select
Remote Access Configuration
and press
<Enter>.
6
In the Remote Access Configuration screen, verify the following settings:
Remote Access: Enabled
Serial port number: COM2 as SOL