Using the System Setup Program 157
After FCB resets, all network and configuration settings restore back to their
default values. FCB is configured with the following default network settings.
IP address: 192.168.0.120
Subnet mask: 255.255.255.0
When the reset to default button is pressed, the FCB status and
identification indicator lights to indicate the following behaviors
Blinking amber (500 ms off/5 s on) — Restarts the FCB firmware and reset
to factory default is completed.
Blinking amber (250 ms off/5 s on) — Restores the default network
settings to their default values.
FCB Configuration Information
The FCB configuration information is stored in the FCB board's internal
EEPROM, instead of the Chassis FRU/EEPROM as it is board level
configuration. Please refer to file format as shown below. Keep all attributes
and key words of the configuration and only modify "value" if it is allowed.
Firmware will drop configuration file if configurations are incorrect when user
uploads the file.
For example, a configuration data should have the following information:
CONNECT.TYPE=STATIC/DHCP
IP=192.168.0.120
NETMASK=255.255.255.0
GATEWAY=192.168.0.1
TRAP.DESTINATION1=0.0.0.0
TRAP.DESTINATION2=0.0.0.0
TRAP.DESTINATION3=0.0.0.0
TRAP.DESTINATION4=0.0.0.0
TRAP.DESTINATION5=0.0.0.0
SNMP.RD.COMMUNITY.STR=public
SNMP.RW.COMMUNITY.STR=private
POWERCAPPING.R=3
POWERCAPPING.W_DELTA=20
POWERCAPPING.K_CNT=3