After FCB resets, all network and configuration settings restore back to their default values. FCB is configured with the following default network settings.
•IP address: 192.168.0.120
•Subnet mask: 255.255.255.0
When the reset to default button is pressed, the FCB status and identification indicator lights to indicate the following behaviors
•Blinking amber (500 ms off/5 s on) — Restarts the FCB firmware and reset to factory default is completed.
•Blinking amber (250 ms off/5 s on) — Restores the default network settings to their default values.
FCB Configuration Information
The FCB configuration information is stored in the FCB board's internal EEPROM, instead of the Chassis FRU/EEPROM as it is board level configuration. Please refer to file format as shown below. Keep all attributes and key words of the configuration and only modify "value" if it is allowed. Firmware will drop configuration file if configurations are incorrect when user uploads the file.
For example, a configuration data should have the following information:
CONNECT.TYPE=STATIC/DHCP
IP=192.168.0.120
NETMASK=255.255.255.0
GATEWAY=192.168.0.1
TRAP.DESTINATION1=0.0.0.0
TRAP.DESTINATION2=0.0.0.0
TRAP.DESTINATION3=0.0.0.0
TRAP.DESTINATION4=0.0.0.0
TRAP.DESTINATION5=0.0.0.0
SNMP.RD.COMMUNITY.STR=public
SNMP.RW.COMMUNITY.STR=private
POWERCAPPING.R=3
POWERCAPPING.W_DELTA=20
POWERCAPPING.K_CNT=3