Chapter 4 Parameters

Group 2 Digital Input/Output Parameters

 

 

 

 

02-00

2-wire/3-wire Operation Control

 

Control

VF

VFPG

SVC FOCPG TQRPG

Factory setting: 0

mode

 

 

 

 

 

 

Settings

0

FWD/STOP, REV/STOP

 

1FWD/STOP, REV/STOP (Line Start Lockout)

2RUN/STOP, REV/FWD

3RUN/STOP, REV/FWD (Line Start Lockout)

43-wire (momentary push button)

53-wire (momentary push button and Line Start Lockout)

Three of the six methods include a “Line Start Lockout” feature. When line start lockout is

enabled, the drive will not run once applying the power. The Line Start Lockout feature doesn’t

guarantee the motor will never start under this condition. It is possible the motor may be set in

motion by a malfunctioning switch.

02-00

Control Circuits of the External Terminal

0, 1

 

FWD:("OPEN":STO P)

2-wire operation control (1)

FWD/STOP

("CLOSE":FWD)

FWD/STOP

REV/STOP

REV:("OPEN": STOP)

REV/STOP

 

("CLOSE": REV)

 

DCM

 

 

VFD-VE

2, 3

 

FWD:("OPEN":STOP)

2-wire operation control (2)

RUN/STOP

("CLOSE":RUN)

RUN/STOP

FWD/REV

REV:("OPEN": FWD)

REV/FWD

 

("CLOSE": REV)

 

DCM

 

 

VFD-VE

4, 5

 

FWD "CLOSE":RUN

3-wire operation control

STOP RUN

 

 

MI1 "OPEN":STOP

 

 

 

REV/FWD

REV/FWD "OPEN": FWD

 

"CLOSE": REV

 

 

DCM

 

 

VFD-VE

02-01Multi-Function Input Command 1 (MI1)

Factory Setting: 1

02-02Multi-Function Input Command 2 (MI2)

Factory Setting: 2

02-03Multi-Function Input Command 3 (MI3)

Factory Setting: 3

Revision August 2008, 03VE, SW V2.04

4-59

Page 108
Image 108
Delta Electronics VFD-VE Series manual Run/Stop, Rev/Fwd, Control Circuits of the External Terminal, Fwd/Stop, Rev/Stop