Delta Electronics VFD-VE Series manual 01-10, Output Frequency Upper Limit Unit, 01-11

Models: VFD-VE Series

1 291
Download 291 pages 55.35 Kb
Page 103
Image 103

Chapter 4 Parameters

Fcmd>Fmi n

NO

 

by Pr.01- 34

 

 

 

 

 

 

 

 

 

 

 

 

Y ES

 

 

 

 

 

 

 

 

 

Fstart>Fmin

NO

fstart=Fmin

 

Flow= 0

Y ES

H=Fc md

 

 

 

 

 

 

 

 

 

Hz

 

 

 

 

 

 

 

 

 

Fcmd

 

 

Y ES

 

 

 

 

 

 

Fmin

 

 

fstart=Fstart

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fstart

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time

 

 

operation after

NO

 

 

 

 

Flow= 0

 

start-up

NO

Fcmd>Fl ow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

Y ES

 

Fcmd<Fmi n

Y ES

by

 

 

 

 

 

 

 

Pr.01- 34

 

 

 

by

NO

 

 

 

 

 

 

 

Fcmd>Fmi n

 

 

 

 

 

 

 

Pr.01- 34

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

Y ES

 

 

 

 

Y ES

 

H=Fl ow

 

 

H=Fc md

 

 

 

 

 

 

 

 

 

 

 

 

H=Fc md

 

Hz

 

 

 

 

 

Hz

 

 

 

 

Hz

 

 

 

 

 

60Hz

H=Fl ow

 

 

 

60Hz

 

 

 

 

 

H=Fc md1

 

Flow

Fcmd

 

 

 

 

 

Flow> Fcmd1

 

 

Fcmd1

 

Fcmd1>Flow &

Fcmd1

>Fmin

 

 

 

 

Fstart

 

 

Fmin

 

Fcmd1>Fmin

Fmin

 

 

Fmin

 

 

Fcmd2

 

 

 

Fcmd2

 

 

 

Time

Flow

 

Time

 

 

 

Time

 

 

 

 

 

 

 

by Pr.01- 34

 

 

 

 

 

by Pr.01- 34

 

 

Fmin>Fc md2

 

 

 

 

 

Fcmd2>Flow &

 

 

 

 

 

 

 

 

Fcmd2<Fmin

 

 

 

 

01-10

Output Frequency Upper Limit

Unit: 0.01

 

Control

VF

VFPG

SVC

FOCPG

Factory Setting: 600.00

 

mode

 

 

 

 

 

 

 

 

 

Settings

0.00~600.00Hz

 

 

01-11

Output Frequency Lower Limit

Unit: 0.01

 

Control

VF

VFPG

SVC

FOCPG

Factory Setting: 0.00

 

mode

 

 

 

 

 

 

 

 

 

Settings

0.00~600.00Hz

 

 

 

 

 

 

 

 

The upper/lower output frequency setting is used to limit the actual output frequency. If the frequency setting is higher than the upper limit, it will run with the upper limit frequency. If output frequency lower than output frequency lower limit and frequency setting is higher than

4-54

Revision August 2008, 03VE, SW V2.04

Page 103
Image 103
Delta Electronics VFD-VE Series manual 01-10, Output Frequency Upper Limit Unit, 01-11, Output Frequency Lower Limit Unit

VFD-VE Series specifications

Delta Electronics VFD-VE Series is a state-of-the-art variable frequency drive (VFD) designed to enhance energy efficiency and improve the operational capabilities of various industrial applications. Renowned for its reliability and performance, the VFD-VE Series serves a diverse range of sectors including manufacturing, HVAC, and water treatment.

One of the primary features of the VFD-VE Series is its advanced control algorithms, which provide precise speed and torque control for AC motors. The series utilizes a vector control method that enables excellent dynamic response and a wide speed range. This is particularly beneficial for applications requiring variable speeds or precise positioning, as it ensures smooth acceleration and deceleration while maintaining optimal performance.

The VFD-VE Series stands out with its Energy Saving Technology. By intelligently optimizing motor control parameters based on the load, the VFD can significantly reduce energy consumption. This built-in functionality not only helps companies save on electricity costs but also contributes to a lower carbon footprint, aligning with global sustainability efforts.

Another key characteristic of the VFD-VE Series is its user-friendly interface. Equipped with a clear and intuitive LCD display, it simplifies monitoring and adjustments, allowing operators to configure settings easily. Additionally, the series supports various communication protocols such as Modbus, EtherCAT, and CANopen, enabling seamless integration with existing control systems for enhanced automation.

The VFD-VE Series is built to withstand harsh industrial environments. Its robust design includes features such as IP20 or IP55 ingress protection ratings, ensuring reliable operation even in dusty or humid conditions. Furthermore, the drives are equipped with advanced thermal management systems that prevent overheating, thereby prolonging the lifespan of the equipment.

Safety is also a priority in the VFD-VE Series, which incorporates multiple safety features such as overvoltage, undervoltage, and overcurrent protection. These safeguards help protect both the drive itself and the connected machinery, minimizing downtime and reducing maintenance costs.

Overall, Delta Electronics VFD-VE Series combines cutting-edge technology, energy efficiency, and robust design to meet the dynamic needs of modern industrial automation. With its advanced features and reliable performance, it is an ideal choice for businesses aiming to optimize their processes and achieve greater energy savings.