Delta Electronics VFD-VE Series manual Version Differences

Models: VFD-VE Series

1 291
Download 291 pages 55.35 Kb
Page 75
Image 75

Chapter 4 Parameters

4.2 Version Differences

4.2.1 Version 2.02

New or update parameter groups are:

Group 2: Digital Input/Output Parameters

Group 3: Analog Input/Output Parameters

Group 6: Protection Parameters

Group 8: High-function PID Parameters

Group 10: Speed Feedback Control Parameters

4.2.2 Version 2.04

New or update parameter groups are:

Group 0 System Parameters

Group 2: Digital Input/Output Parameters

Group 3: Analog Input/Output Parameters

Group 5: Motor Parameters

Group 6: Protection Parameters

Group 8: High-function PID Parameters

Group 10: Speed Feedback Control Parameters

Version 2.02

Group 2 Digital Input/Output Parameters

New settings are marked in bold. In version 2.02, the parameters are from Pr.02-00 to Pr.02-34.

 

Pr.

Explanation

Settings

Factory

VF

VFPG

SVC

FOCPG

TQRPG

 

 

 

 

Setting

 

 

 

 

 

 

02-01

Multi-Function Input Command 1 (MI1)

27: ASR1/ASR2 selection

 

 

 

 

 

 

(it is Stop terminal for 3-wire operation)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02-02

Multi-Function Input Command 2 (MI2)

28: Emergency stop (EF1)

 

 

02-03

Multi-Function Input Command 3 (MI3)

29: Signal confirmation for Y-connection

 

 

 

02-04

Multi-Function Input Command 4 (MI4)

30: Signal confirmation for Δ−connection

 

 

 

02-05

Multi-Function Input Command 5 (MI5)

31: High torque bias (by Pr.07-29)

 

 

02-06

Multi-Function Input Command 6 (MI6)

32: Middle torque bias (by Pr.07-30)

 

 

 

(specific terminal for TRG)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02-23

Multi-Function Input Command 7

33: Low torque bias (by Pr.07-31)

 

 

02-24

Multi-Function Input Command 8

34: Enable multi-step position control

 

 

 

 

 

02-25

Multi-Function Input Command 9

35: Enable position control

 

 

 

 

 

02-26

Multi-Function Input Command 10

36: Enable position learning function

 

 

 

 

 

 

 

(valid at stop)

 

 

 

 

 

 

 

02-27

Multi-Function Input Command 11

37: Enable pulse position input

 

 

 

 

 

 

 

command

 

 

 

 

 

 

 

02-28

Multi-Function Input Command 12

38: Disable write EEPROM function

 

 

02-29

Multi-Function Input Command 13

39: Torque command direction

 

 

 

 

 

 

02-30

Multi-Function Input Command 14

40: Force stop

 

 

 

 

41: Serial position clock

 

 

 

 

 

 

 

 

42: Serial position input

 

 

 

 

 

 

 

 

43: Analog input resolution selection

 

 

 

 

 

02-11

Multi-function Output 1 RA, RB,

29: Output when frequency >= Pr.02-33

 

RC(Relay1)

 

 

 

 

 

 

 

02-12

Multi-function Output 2

30: Output when frequency < Pr.02-33

 

MRA, MRC (Relay2)

 

 

 

 

 

 

 

02-13

Multi-function Output 3 (MO1)

31: Y-connection for the motor coil

 

 

Multi-function Output 4 (MO2)

 

 

 

 

 

 

 

02-14

32: Δ connection for the motor coil

 

 

 

 

 

 

 

 

 

 

4-26

Revision August 2008, 03VE, SW V2.04

Page 75
Image 75
Delta Electronics VFD-VE Series manual Version Differences

VFD-VE Series specifications

Delta Electronics VFD-VE Series is a state-of-the-art variable frequency drive (VFD) designed to enhance energy efficiency and improve the operational capabilities of various industrial applications. Renowned for its reliability and performance, the VFD-VE Series serves a diverse range of sectors including manufacturing, HVAC, and water treatment.

One of the primary features of the VFD-VE Series is its advanced control algorithms, which provide precise speed and torque control for AC motors. The series utilizes a vector control method that enables excellent dynamic response and a wide speed range. This is particularly beneficial for applications requiring variable speeds or precise positioning, as it ensures smooth acceleration and deceleration while maintaining optimal performance.

The VFD-VE Series stands out with its Energy Saving Technology. By intelligently optimizing motor control parameters based on the load, the VFD can significantly reduce energy consumption. This built-in functionality not only helps companies save on electricity costs but also contributes to a lower carbon footprint, aligning with global sustainability efforts.

Another key characteristic of the VFD-VE Series is its user-friendly interface. Equipped with a clear and intuitive LCD display, it simplifies monitoring and adjustments, allowing operators to configure settings easily. Additionally, the series supports various communication protocols such as Modbus, EtherCAT, and CANopen, enabling seamless integration with existing control systems for enhanced automation.

The VFD-VE Series is built to withstand harsh industrial environments. Its robust design includes features such as IP20 or IP55 ingress protection ratings, ensuring reliable operation even in dusty or humid conditions. Furthermore, the drives are equipped with advanced thermal management systems that prevent overheating, thereby prolonging the lifespan of the equipment.

Safety is also a priority in the VFD-VE Series, which incorporates multiple safety features such as overvoltage, undervoltage, and overcurrent protection. These safeguards help protect both the drive itself and the connected machinery, minimizing downtime and reducing maintenance costs.

Overall, Delta Electronics VFD-VE Series combines cutting-edge technology, energy efficiency, and robust design to meet the dynamic needs of modern industrial automation. With its advanced features and reliable performance, it is an ideal choice for businesses aiming to optimize their processes and achieve greater energy savings.