07-00

Software Brake Level

 

Unit: 0.1

 

Control

VF

VFPG

SVC

FOCPG TQRPG

 

 

mode

 

 

 

 

 

 

 

 

 

Settings

230V series

350.0~450.0Vdc

Factory Setting: 380.0

 

 

 

460V series

700.0~900.0Vdc

Factory Setting: 760.0

 

 

 

This parameter sets the DC-bus voltage at which the brake chopper is activated.

 

 

 

07-01

DC Brake Current Level

Unit: 1

 

Control

VF

VFPG

SVC

FOCPG TQRPG

Factory Setting: 0

 

mode

 

 

 

 

 

 

 

 

 

Settings

 

0 to 100%

 

 

 

 

 

 

 

 

This parameter sets the level of DC Brake Current output to the motor during start-up and stopping. When setting DC Brake Current, the Rated Current (Pr.00-01) is regarded as 100%. It is recommended to start with a low DC Brake Current Level and then increase until proper holding torque has been attained.

When it is in FOCPG/TQRPG mode, it can enable DC brake function by setting to any value.

07-02

DC Brake Time during Start-up

Unit: 0.1

Control

VF

VFPG SVC FOCPG TQRPG

Factory Setting: 0.0

mode

 

 

 

 

 

Settings

0.0 to 60.0 sec

 

This parameter determines the duration of the DC Brake current after a RUN command. When the time has elapsed, the AC motor drive will start accelerating from the Minimum Frequency (Pr.01-05).

07-03

DC Brake Time during Stopping

Unit: 0.01

 

Control

VF

VFPG

SVC

FOCPG TQRPG

Factory Setting: 0.00

 

mode

 

 

 

 

 

 

 

 

 

Settings

 

0.00 to 60.00 sec

 

 

 

 

 

This parameter determines the duration of the DC Brake current during stopping.

 

 

 

 

 

07-04

Start-Point for DC Brake

Unit: 0.01

 

Control

VF

VFPG

SVC

TQRPG

Factory Setting: 0.00

 

mode

 

 

 

 

 

 

 

 

 

Settings

 

0.00 to 600.00Hz

 

 

 

 

 

 

 

 

This parameter determines the frequency when DC Brake will begin during deceleration.

Revision August 2008, 03VE, SW V2.04

4-107

Page 156
Image 156
Delta Electronics VFD-VE Series manual 07-00, 07-01, 07-02, 07-03, 07-04

VFD-VE Series specifications

Delta Electronics VFD-VE Series is a state-of-the-art variable frequency drive (VFD) designed to enhance energy efficiency and improve the operational capabilities of various industrial applications. Renowned for its reliability and performance, the VFD-VE Series serves a diverse range of sectors including manufacturing, HVAC, and water treatment.

One of the primary features of the VFD-VE Series is its advanced control algorithms, which provide precise speed and torque control for AC motors. The series utilizes a vector control method that enables excellent dynamic response and a wide speed range. This is particularly beneficial for applications requiring variable speeds or precise positioning, as it ensures smooth acceleration and deceleration while maintaining optimal performance.

The VFD-VE Series stands out with its Energy Saving Technology. By intelligently optimizing motor control parameters based on the load, the VFD can significantly reduce energy consumption. This built-in functionality not only helps companies save on electricity costs but also contributes to a lower carbon footprint, aligning with global sustainability efforts.

Another key characteristic of the VFD-VE Series is its user-friendly interface. Equipped with a clear and intuitive LCD display, it simplifies monitoring and adjustments, allowing operators to configure settings easily. Additionally, the series supports various communication protocols such as Modbus, EtherCAT, and CANopen, enabling seamless integration with existing control systems for enhanced automation.

The VFD-VE Series is built to withstand harsh industrial environments. Its robust design includes features such as IP20 or IP55 ingress protection ratings, ensuring reliable operation even in dusty or humid conditions. Furthermore, the drives are equipped with advanced thermal management systems that prevent overheating, thereby prolonging the lifespan of the equipment.

Safety is also a priority in the VFD-VE Series, which incorporates multiple safety features such as overvoltage, undervoltage, and overcurrent protection. These safeguards help protect both the drive itself and the connected machinery, minimizing downtime and reducing maintenance costs.

Overall, Delta Electronics VFD-VE Series combines cutting-edge technology, energy efficiency, and robust design to meet the dynamic needs of modern industrial automation. With its advanced features and reliable performance, it is an ideal choice for businesses aiming to optimize their processes and achieve greater energy savings.