Delta Electronics VFD-VE Series manual 10-16, 10-17, 10-18, 10-19

Models: VFD-VE Series

1 291
Download 291 pages 55.35 Kb
Page 203
Image 203

Chapter 4 Parameters

4

Phase A is a pulse input and phase B is a direction input. (low input=forward direction, high input=reverse direction)

FWDREV

A

B

 

10-16

Output Setting for Frequency Division (denominator)

Unit: 1

 

 

 

 

 

 

 

Control

VFPG

FOCPG TQRPG

Factory Setting: 1

 

mode

 

 

 

 

 

 

 

 

Settings

 

1 to 255

 

 

This parameter is used to set the denominator for frequency division. For example, when it is

 

set to 2 with feedback 1024ppr, PG output will be 1024/2=512ppr.

 

 

 

 

 

10-17

PG Electrical Gear A (Channel 1 of PG card)

Unit: 1

 

 

 

 

 

 

 

Control

VFPG

FOCPG

Factory Setting: 100

 

mode

 

 

 

 

 

 

 

 

Settings

1 to 5000

 

 

 

 

 

10-18

PG Electrical Gear B (Channel 2 of PG card)

Unit: 1

 

 

 

 

 

 

 

Control

VFPG

FOCPG

Factory Setting: 100

 

mode

 

 

 

 

 

 

 

 

Settings

1 to 5000

 

 

 

 

Rotation speed = pulse frequency/encoder pulse (Pr.10-00) * PG Electrical Gear A / PG

 

Electrical Gear B.

 

 

 

 

 

 

10-19

PG Position Control Point (Home)

Unit: 1

 

 

 

 

 

 

 

Control

VFPG

FOCPG

Factory Setting: 0

 

mode

 

 

 

 

 

 

 

 

Settings

 

0 to 20000

 

 

 

 

 

This parameter determines the home position in the position control.

 

4-154

Revision August 2008, 03VE, SW V2.04

Page 203