Delta Electronics VFD-VE Series manual 10-02, 10-03, 10-04, 10-05, 10-06, 10-07, 10-08

Models: VFD-VE Series

1 291
Download 291 pages 55.35 Kb
Page 200
Image 200

 

 

 

 

 

Chapter 4 Parameters

 

 

 

 

 

 

10-02

PG Feedback Fault Treatment

 

 

 

 

 

 

 

 

 

 

Control

VFPG FOCPG TQRPG

 

Factory Setting: 2

 

mode

 

 

 

 

 

 

 

 

 

 

Settings

0

Warn and keep operating

 

 

 

 

 

1

Warn and RAMP to stop

 

 

 

 

 

2

Warn and COAST to stop

 

 

 

 

 

 

 

10-03

Detection Time for PG Feedback Fault

 

Unit: 0.01

 

 

 

 

 

 

Factory Setting: 1.00

 

Control

VFPG FOCPG TQRPG

 

 

mode

 

 

 

 

 

 

 

 

 

 

Settings

0.00 to 10.00 sec

 

 

When PG loss, encoder signal error, pulse signal setting error or signal error, if time exceeds the detection time for PG feedback fault (Pr.10-03), the PG signal error will occur. Refer to the Pr.10-02 for PG feedback fault treatment.

 

10-04

ASR (Auto Speed Regulation) control (P) 1

 

Unit: 0.1

 

 

 

 

 

 

 

Factory Setting: 10

 

Control

VFPG FOCPG

 

 

 

 

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Settings

0 to 40 Hz

 

 

 

 

 

 

 

10-05

ASR (Auto Speed Regulation) control (I) 1

 

Unit: 0.001

 

 

 

 

 

 

 

Factory Setting: 0.100

 

Control

VFPG FOCPG

 

 

 

 

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Settings

0.000 to 10.000 sec

 

 

 

 

 

 

 

 

 

 

 

10-06

ASR (Auto Speed Regulation) control (P) 2

 

Unit: 0.1

 

 

 

 

 

 

 

Factory Setting: 10

 

Control

VFPG FOCPG

 

 

 

 

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Settings

0 to 40Hz

 

 

 

 

 

 

 

 

 

 

 

10-07

ASR (Auto Speed Regulation) control (I) 2

 

Unit: 0.001

 

 

 

 

 

 

 

Factory Setting: 0.100

 

Control

VFPG FOCPG

 

 

 

 

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Settings

0.000 to 10.000 sec

 

 

 

 

 

 

 

10-08

ASR 1/ASR2 Switch Frequency

 

Unit: 0.01

 

 

 

 

 

 

 

Factory Setting: 7.00

 

Control

VFPG FOCPG

 

 

 

 

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Settings

5.00 o 600.00Hz

 

 

 

 

 

 

 

 

 

 

ASR P determines Proportional control and associated gain (P). ASR I determines integral control and associated gain (I).