Delta Electronics VFD-VE Series manual RTU mode, Stx

Models: VFD-VE Series

1 291
Download 291 pages 55.35 Kb
Page 188
Image 188

Character

 

 

 

 

Chapter 4 Parameters

 

‘8’

‘9’

‘A’

‘B’

‘C’

‘D’

‘E’

 

‘F’

ASCII code

38H

39H

41H

42H

43H

44H

45H

 

46H

RTU mode:

Each 8-bit data is the combination of two 4-bit hexadecimal characters. For example, 64

Hex.

2. Data Format

10-bit character frame (For ASCII):

 

( 7.N.2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start

0

1

2

3

4

5

6

Stop

Stop

 

 

 

bit

bit

bit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-bit character

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

-bit character frame

 

 

 

 

 

 

 

 

( 7.E.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start

0

1

2

3

4

5

6

Even

Stop

 

 

 

 

bit

parity

bit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-bit character

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

-bit character frame

 

 

 

 

 

 

 

 

( 7.O.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start

0

1

2

3

4

5

6

Odd

Stop

 

 

 

bit

parity

bit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-bit character

10-bit character frame

11-bit character frame (For RTU):

( 8.N.2 )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start

0

1

2

3

4

5

6

7

Stop

Stop

 

 

bit

bit

bit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8-bit character

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

-bit character frame

 

 

 

 

 

 

 

( 8.E.1 )

 

 

 

 

Even

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start

0

1

2

3

4

5

6

7

Stop

 

 

bit

parity

bit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8-bit character

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

-bit character frame

 

 

 

 

 

 

 

( 8.O.1 )

 

 

 

 

 

Odd

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start

0

1

2

3

4

5

6

7

Stop

 

 

bit

parity

bit

 

 

 

 

 

 

 

 

 

 

 

 

 

8-bit character

11-bit character frame

3. Communication Protocol

3.1 Communication Data Frame:

ASCII mode:

STX

Start character ‘:’ (3AH)

Address Hi

Communication address:

Address Lo

8-bit address consists of 2 ASCII codes

Function Hi

Command code:

Function Lo

8-bit command consists of 2 ASCII codes

Revision August 2008, 03VE, SW V2.04

4-139

Page 188
Image 188
Delta Electronics VFD-VE Series manual RTU mode, Stx