Chapter 4 Parameters

 

 

Settings

 

Control Mode

 

 

 

 

 

VF

VFPG

SVC

FOCPG

TQRPG

 

 

 

13: cancel the setting of the optimal

 

 

 

 

acceleration/deceleration time

 

 

 

 

 

 

 

 

14: switch between drive settings 1 and 2

 

 

 

 

15: operation speed command form AVI

 

 

 

 

16: operation speed command form ACI

 

 

 

 

17: operation speed command form AUI

 

 

 

 

18: Emergency Stop (07-36)

 

 

19: Digital Up command

 

 

 

 

20: Digital Down command

 

 

 

 

21: PID function disabled

 

 

 

 

22: clear counter

 

 

23: input the counter value (multi-function input command

 

6)

 

 

 

 

 

 

 

 

24: FWD JOG command

 

 

 

 

25: REV JOG command

 

 

 

 

26: TQC+PG/FOC+PG model selection

 

 

27: ASR1/ASR2 selection

 

 

 

 

28: Emergency stop (EF1)

 

 

29: Signal confirmation for Y-connection

 

 

 

 

30: Signal confirmation for connection

 

 

 

 

31: High torque bias (by Pr.07-29)

 

 

32: Middle torque bias (by Pr.07-30)

 

 

33: Low torque bias (by Pr.07-31)

 

 

34: Enable multi-step position control

 

 

 

 

 

 

35: Enable position control

 

 

 

 

36: Enable position learning function (valid at stop)

 

 

 

 

 

 

37: Enable pulse position input command

 

 

 

 

38: Disable write EEPROM function

 

 

39: Torque command direction

 

 

 

 

 

 

40: Force stop

 

 

41: Serial position clock

 

 

 

 

 

 

 

42: Serial position input

 

 

 

 

 

 

 

43: Analog input resolution selection

 

 

 

 

 

 

 

44: Reset initial reel diameter

 

 

45: Reset initial reel diameter 0

 

 

46: Reset initial reel diameter 1

 

 

47: Reset PID control integration of tension

 

 

48: Mechanical Gear Ratio Switch

 

 

 

 

49: Reserved

 

 

 

 

 

 

 

 

50: Reserved

 

 

 

 

 

 

This parameter selects the functions for each multi-function terminal.

The terminals of Pr.02-23~Pr.02-27 are virtual and set as MI7~MIB when using with optional card EMV-APP01

If Pr.02-00 is set to 3-wire operation control. Terminal MI1 is needed for the 3rd wire position. Therefore, MI1 is not allowed for any other operation.

Multi-function input commands 7-14 are the extension terminals of Pr.02-01 to Pr.02-06. There are 14 terminals but the terminals 7-14 are virtual terminals and you can set the status of bit 8- 15 of Pr.02-10 to ON or OFF by KPV-CE01 or communication.

Revision August 2008, 03VE, SW V2.04