Delta Electronics VFD-VE Series manual 0FH

Models: VFD-VE Series

1 291
Download 291 pages 55.35 Kb
Page 191
Image 191

Chapter 4 Parameters

 

 

 

 

 

 

00H

 

 

00H

 

Data content

17H

 

Data content

17H

 

70H

 

70H

 

 

 

 

 

CRC CHK Low

86H

 

CRC CHK Low

86H

 

CRC CHK High

22H

 

CRC CHK High

22H

(3)10H: write multiple registers (write multiple data to registers) Example: Set the multi-step speed,

Pr.05-00=50.00 (1388H), Pr.05-01=40.00 (0FA0H). AC drive address is 01H. ASCII Mode:

Command message:

STX

‘:’

Address 1

‘0’

Address 0

‘1’

Function 1

‘1’

Function 0

‘0’

Starting data

‘0’

‘5’

address

‘0’

 

‘0’

Number of data

‘0’

‘0’

(count by word)

‘0’

 

‘2’

Number of data

‘0’

(count by byte)

‘4’

 

‘1’

The first data

‘3’

content

‘8’

 

‘8’

 

‘0’

The second data

‘F’

content

‘A’

 

‘0’

LRC Check

‘9’

‘A’

 

END

CR

LF

 

RTU mode:

Command message:

Address

01H

Function

10H

Starting data

05H

address

00H

Number of data

00H’

(count by word)

02H

Number of data

04

(count by byte)

 

The first data

13H

content

88H

The second data

0FH

Response message:

STX

‘:’

Address 1

‘0’

Address 0

‘1’

Function 1

‘1’

Function 0

‘0’

Starting data

‘0’

‘5’

address

‘0’

 

‘0’

Number of data

‘0’

‘0’

(count by word)

‘0’

 

‘2’

LRC Check

‘E’

‘8’

 

END

CR

LF

 

Response message:

Address

01H

Function

10H

Starting data address

05H

Number of data

00H

00H

(count by word)

02H

CRC Check Low

41H

 

 

CRC Check High

04H

4-142

Revision August 2008, 03VE, SW V2.04

Page 191
Image 191
Delta Electronics VFD-VE Series manual 0FH