Pr.

Explanation

Settings

Factory

VF

VFPG

SVC

FOCPG

TQRPG

 

 

 

 

Setting

 

 

 

 

 

01-00

Maximum Output

50.00~600.00Hz

60.00/

Frequency

 

50.00

 

 

 

 

 

 

 

 

 

 

 

 

 

01-01

1st Output Frequency

0.00~600.00Hz

60.00/

Setting 1

 

50.00

 

 

 

 

 

 

 

 

 

 

 

 

 

01-02

1st Output Voltage

230V: 0.1V~255.0V

220.0

Setting 1

460V: 0.1V~510.0V

440.0

 

 

 

 

 

 

 

 

 

 

 

 

01-03

2nd Output Frequency

0.00~600.00Hz

0.50

 

 

 

Setting 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01-04

2nd Output Voltage

230V: 0.1V~255.0V

5.0

 

 

 

Setting 1

460V: 0.1V~510.0V

10.0

 

 

 

 

 

01-05

3rd Output Frequency

0.00~600.00Hz

0.50

 

 

 

Setting 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01-06

3rd Output Voltage

230V: 0.1V~255.0V

5.0

 

 

 

Setting 1

460V: 0.1V~510.0V

10.0

 

 

 

 

 

01-07

4th Output Frequency

0.00~600.00Hz

0.00

 

Setting 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01-08

4th Output Voltage

230V: 0.1V~255.0V

0.0

 

 

Setting 1

460V: 0.1V~510.0V

0.0

 

 

 

 

 

 

01-09

Start Frequency

0.00~600.00Hz

0.50

 

 

01-10

Output Frequency Upper

0.00~600.00Hz

600.00

 

Limit

 

 

 

 

 

 

 

01-11

Output Frequency Lower

0.00~600.00Hz

0.00

 

Limit

 

 

 

 

 

 

 

01-12

Accel Time 1

0.00~600.00 sec/0.00~6000.0 sec

10.00/

 

10.0

 

 

 

 

 

 

01-13

Decel Time 1

0.00~600.00 sec/0.00~6000.0 sec

10.00/

 

10.0

 

 

 

 

 

 

01-14

Accel Time 2

0.00~600.00 sec/0.00~6000.0 sec

10.00/

 

10.0

 

 

 

 

 

 

01-15

Decel Time 2

0.00~600.00 sec/0.00~6000.0 sec

10.00/

 

10.0

 

 

 

 

 

 

01-16

Accel Time 3

0.00~600.00 sec/0.00~6000.0 sec

10.00/

 

10.0

 

 

 

 

 

 

01-17

Decel Time 3

0.00~600.00 sec/0.00~6000.0 sec

10.00/

 

10.0

 

 

 

 

 

 

01-18

Accel Time 4

0.00~600.00 sec/0.00~6000.0 sec

10.00/

 

10.0

 

 

 

 

 

 

01-19

Decel Time 4

0.00~600.00 sec/0.00~6000.0 sec

10.00/

 

 

10.0

 

 

 

 

 

 

01-20

JOG Acceleration Time

0.00~600.00 sec/0.00~6000.0 sec

1.00/

 

1.0

 

 

 

 

 

 

01-21

JOG Deceleration Time

0.00~600.00 sec/0.00~6000.0 sec

1.00/

 

1.0

 

 

 

 

 

 

01-22

JOG Frequency

0.00~600.00Hz

6.00

 

01-23

1st/4th Accel/decel

0.00~600.00Hz

0.00

 

Frequency

 

 

 

 

 

 

 

 

01-24

S-curve for Acceleration

0.00~25.00 sec/0.00~250.0 sec

0.2/0.0

 

Departure Time 1

 

 

 

 

 

 

 

 

01-25

S-curve for Acceleration

0.00~25.00 sec /0.00~250.0 sec

0.2/0.0

 

Arrival Time 2

 

 

 

 

 

 

 

 

01-26

S-curve for Deceleration

0.00~25.00 sec /0.00~250.0 sec

0.2/0.0

 

Departure Time 1

 

 

 

 

 

 

 

 

01-27

S-curve for Deceleration

0.00~25.00 sec /0.00~250.0 sec

0.2/0.0

 

Arrival Time 2

 

 

 

 

 

 

 

01-28

Skip Frequency 1 (upper

0.00~600.00Hz

0.00

 

limit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01-29

Skip Frequency 1 (lower

0.00~600.00Hz

0.00

 

limit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01-30

Skip Frequency 2 (upper

0.00~600.00Hz

0.00

 

limit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01-31

Skip Frequency 2 (lower

0.00~600.00Hz

0.00

 

limit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01-32

Skip Frequency 3 (upper

0.00~600.00Hz

0.00

 

limit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01-33

Skip Frequency 3 (lower

0.00~600.00Hz

0.00

 

limit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01-34

Mode Selection when

0: Output Waiting

0

 

1: Zero-speed operation

 

 

 

 

 

 

Frequency < Fmin

 

 

 

 

 

 

 

 

2: Fmin (4th output frequency setting)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01-35

1st Output Frequency

0.00~600.00Hz

60.00/

4-4

Revision August 2008, 03VE, SW V2.04

Page 53
Image 53
Delta Electronics VFD-VE Series manual Group 1 Basic Parameters

VFD-VE Series specifications

Delta Electronics VFD-VE Series is a state-of-the-art variable frequency drive (VFD) designed to enhance energy efficiency and improve the operational capabilities of various industrial applications. Renowned for its reliability and performance, the VFD-VE Series serves a diverse range of sectors including manufacturing, HVAC, and water treatment.

One of the primary features of the VFD-VE Series is its advanced control algorithms, which provide precise speed and torque control for AC motors. The series utilizes a vector control method that enables excellent dynamic response and a wide speed range. This is particularly beneficial for applications requiring variable speeds or precise positioning, as it ensures smooth acceleration and deceleration while maintaining optimal performance.

The VFD-VE Series stands out with its Energy Saving Technology. By intelligently optimizing motor control parameters based on the load, the VFD can significantly reduce energy consumption. This built-in functionality not only helps companies save on electricity costs but also contributes to a lower carbon footprint, aligning with global sustainability efforts.

Another key characteristic of the VFD-VE Series is its user-friendly interface. Equipped with a clear and intuitive LCD display, it simplifies monitoring and adjustments, allowing operators to configure settings easily. Additionally, the series supports various communication protocols such as Modbus, EtherCAT, and CANopen, enabling seamless integration with existing control systems for enhanced automation.

The VFD-VE Series is built to withstand harsh industrial environments. Its robust design includes features such as IP20 or IP55 ingress protection ratings, ensuring reliable operation even in dusty or humid conditions. Furthermore, the drives are equipped with advanced thermal management systems that prevent overheating, thereby prolonging the lifespan of the equipment.

Safety is also a priority in the VFD-VE Series, which incorporates multiple safety features such as overvoltage, undervoltage, and overcurrent protection. These safeguards help protect both the drive itself and the connected machinery, minimizing downtime and reducing maintenance costs.

Overall, Delta Electronics VFD-VE Series combines cutting-edge technology, energy efficiency, and robust design to meet the dynamic needs of modern industrial automation. With its advanced features and reliable performance, it is an ideal choice for businesses aiming to optimize their processes and achieve greater energy savings.