Delta Electronics VFD-VE Series manual Reserved Example of crane function, 02-15

Models: VFD-VE Series

1 291
Download 291 pages 55.35 Kb
Page 123
Image 123

Chapter 4 Parameters

Settings

Functions

Descriptions

 

 

 

50 Reserved Example of crane function

F requenc y command

Freq. command<02-33

Freq. command>02-31or output c urrent < 02- 32 & output c urrent >02- 32

multi-function output

 

 

MO= 42 (Ac ti ve when

 

 

Fcom>=02-33, output

 

 

current> 02- 32 and time

02-31

02-31

>02-31)

 

 

It is recommended to be used with Dwell function (Pr.07-15 to Pr.07-18) as shown in the following:

Output Freq.

Multi-functioni output MO= 42

( Activate when Fcmd >= 02-33 output current > 02-32 Time > 02-31)

Mechanical breaker

Set 07-16=02-33and

 

Set 07-18=02-33 and

output current >02-32

 

output current <02-32

 

 

 

 

 

 

07-18 Dwell Freq.

07-16 Dwell

 

 

 

at Decel.

Freq.

 

 

 

 

at Accel.

 

 

 

 

 

 

07-15

 

07-17

 

 

Dwell Time at Accel.

 

Dwell Time atDecel.

02-31

02-31 Brake Delay Time Brake Delay

Crane function will be activated when setting 07-16=02-33 and Fcmd>02-33 and output current>02-32 and

Time > 02-31

02-15

Multi-output Direction

 

Unit:1

Control

VF

VFPG SVC

FOCPG TQRPG

Factory setting: 0

mode

 

 

 

 

 

 

Settings

0 ~ 65535

 

 

 

 

 

 

 

This parameter is set via bit setting. If a bit is 1, the corresponding output acts in the opposite way.

Example:

If Pr02-11=1 and Pr02-15=0, Relay 1 RA-RC is closed when the drive runs and is open when the drive is stopped.

4-74

Revision August 2008, 03VE, SW V2.04