Chapter 4 Parameters

 

Control

VF

VFPG

SVC

FOCPG TQRPG

Factory Setting: 1

 

mode

 

 

 

 

 

 

 

 

 

 

 

Settings

 

1 to 10000ppr

 

 

 

 

 

 

 

 

 

 

 

 

08-50

Coil Number for Each Layer

Unit: 1

 

Control

VF

VFPG

SVC

FOCPG TQRPG

Factory Setting: 1

 

mode

 

 

 

 

 

 

 

 

 

 

 

Settings

 

1 to 10000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

08-51

Material Thickness

 

 

 

Unit: 0.001

 

Control

VF

VFPG

SVC

FOCPG TQRPG

Factory Setting: 1.000

 

mode

 

 

 

 

 

 

 

 

 

 

 

Settings

 

0.001 to 60.000mm

 

 

 

 

 

 

 

 

 

 

08-52

Filter Time of Reel Diameter

Unit: 0.01

 

Control

VF

VFPG

SVC

FOCPG TQRPG

Factory Setting: 1.00

 

mode

 

 

 

 

 

 

 

 

 

 

 

Settings

 

0.00 to 100.00 sec

 

 

 

 

 

 

 

 

 

 

This parameter can be used to improve unstable of the source of reel diameter(Pr.08-42).

08-53Auto Compensation of Reel Diameter

Control

VF

VFPG

SVC

FOCPG TQRPG

 

Factory Setting: 0

mode

 

 

 

 

 

 

 

 

 

 

Settings

0

 

Disable

 

 

 

 

1

 

Enable

 

 

 

 

 

 

 

 

 

 

 

 

 

08-54

Current Reel Diameter

 

 

Unit: 0.1

Control

VF

VFPG

SVC

FOCPG TQRPG

 

Factory Setting: 1.0

mode

 

 

 

 

 

 

 

 

 

 

Settings

1.0 to 6000.0 mm

 

 

When the AC motor drive is not at STOP, this parameter is read-only.

08-55Smart Start

Control

VF

VFPG SVC FOCPG TQRPG

Factory Setting: 0

mode

 

 

 

 

Settings 0 Disable

1Enable

2In unwind mode, rewind in reverse direction

 

08-56

Switch Level for Smart Start and PID Function

Unit: 1

 

Control

VF

VFPG SVC FOCPG TQRPG

Factory Setting: 15.0

 

mode

 

 

 

 

 

4-132

Revision August 2008, 03VE, SW V2.04