Chapter 4 Parameters

Settings

0.00~100.00 sec

08-71

Reserved

08-75

08-76Source of Tension Setting

Control

TQRPG

 

 

Factory Setting: 0

mode

 

 

 

 

 

 

Settings

0

Communication RS-485 (Pr.08-78)

 

 

 

 

1

Analog input (Pr. 03-00~03-02 is set to 15 tension setting) (Pr.08-78)

 

 

 

 

 

 

 

 

 

 

 

 

08-77

 

Max. Tension

 

 

Unit: 1

Control

TQRPG

 

 

Factory Setting: 0

mode

 

 

 

 

 

 

Settings

0 ~30000 N

 

 

 

 

 

 

 

 

 

 

 

08-78

 

Tension Setting

 

Unit: 1

Control

TQRPG

 

 

Factory Setting: 0

mode

 

 

 

 

 

 

Settings

0 ~30000 N

 

 

 

 

 

08 - 79

Source of Zero-speed Tension Setting

 

Control

TQRPG

 

 

Factory Setting: 0

mode

 

 

 

 

 

 

Settings

0

Disable

 

 

 

 

1

Communication RS-485 (Pr.08-80)

 

 

 

 

2

Analog input (Pr. 03-00~03-02 is set to 16 zero-speed tension)

 

 

 

 

(Pr.08-80)

 

 

 

 

 

08-80

 

Setting of Zero-speed Tension

Unit: 1

Control

TQRPG

 

 

Factory Setting: 0

mode

 

 

 

 

 

 

Settings

0 ~30000 N

 

 

 

 

 

08 - 81

Source of Tension Taper

 

Control

TQRPG

 

 

Factory Setting: 0

mode

 

 

 

 

 

 

Settings

0

Communication RS-485 (Pr.08-82)

 

 

 

 

1

Analog input (Pr. 03-00~03-02 is set to 17 tension taper) (Pr.08-82)

 

 

 

 

 

 

 

 

 

 

08-82

 

Tension Taper

 

Unit: 1