Chapter 1 Introduction

 

 

 

 

 

 

 

 

Air Temperature:

 

-10 ~ +40°C (14 ~ 122°F)

 

 

 

Relative Humidity:

<90%, no condensation allowed

 

 

 

 

 

 

Operation

Atmosphere

86 ~ 106 kPa

 

 

pressure:

 

 

 

 

 

Installation Site

<1000m

 

 

Altitude:

 

 

 

 

 

 

Vibration:

 

<20Hz: 9.80 m/s2 (1G) max

 

 

 

 

20 ~ 50Hz: 5.88 m/s2 (0.6G) max

 

 

 

 

 

 

Temperature:

-20°C ~ +60°C (-4°F ~ 140°F)

 

 

 

 

 

Storage

Relative Humidity:

 

<90%, no condensation allowed

 

 

 

Transportation

Atmosphere

86 ~ 106 kPa

 

 

pressure:

 

 

 

 

 

 

Vibration:

 

<20Hz: 9.80 m/s2 (1G) max

 

 

 

 

20 ~ 50Hz: 5.88 m/s2 (0.6G) max

 

 

 

 

 

Pollution Degree

2: good for a factory type environment.

 

 

 

 

 

 

Minimum Mounting Clearances

H

Air Flow

W W

H

HP

W

H

mm (inch)

mm (inch)

 

1-5HP

50 (2)

150 (6)

7.5-20HP

75 (3)

175 (7)

25-75HP

75 (3)

200 (8)

100HP and above

75 (3)

250 (10)

Revision August 2008, 03VE, SW V2.04