Diverter Assembly

Caution Support the Diverter Assembly access door during this procedure to prevent
damage to the plastic hinge pins.
1Open the Diverter Assembly access door and release the support struts
(Figure 6-12, callout 1) by sliding the strut ends forward and downward.
2Remove (6) self-tapping screws, CH106 (Figure 6-12, callout 2).
Note The access door support struts will fall free when the Diverter Assembly is
lifted away from the access door.
3Lift the Diverter Assembly up and away from the access door.
Diverter Assembly
Figure 6-12
6Removal and
Replacement