Tray 4 Adjustment Procedure

In some cases, the registration from Tray 4 (HCI) causes print to start too
close to the edge of the paper. This situation is not a typical occurrence. In
most cases the Tray 4 offset is fine. Although this may or may not be within
specification, it is unacceptable to some users. Perform the following
adjustment procedure to correct the situation.
1With the HCI stand-alone, remove left, right and rear covers from the HCI.
2Remove the vertical transfer unit.
3Open the HCI paper tray.
4Loosen both screws that support the paper tray locking bracket on the right
side of the HCI (see Figure 4-3).
5Locate the bracket hole and pin at the middle (right side) (see Figure 4-3).
6Slide the bracket so that the locating pin is positioned at the middle of the
bracket hole.
7Tighten both screws.
8Loosen both screws that support the paper tray locking bracket on the left
side of the HCI.
9Locate the bracket hole and pin at the middle (left side).
Slide the bracket so the locating pin is positioned at the middle of the
bracket hole.
(continued on next page)
Locking
Bracket
Hole
Screw 1
Locating
Pin
Screw 2
HCI
Closing Lever Locking
Bracket
Figure 4-3
4Maintenance &
Adjustments
Maintenance and Adjustments 4-9