Lower Elevator Pulley Assemblies

1Remove all paper bins and the blind cover (see Figure 6-86).
2From the front of the unit, disconnect (2) tension springs (Figure 6-77,
callout 1).
3From the back of the unit, release (2) lower pulley assemblies by pushing
down on the assembly, and then pushing it forward (Figure 6-78, callout 2).
Note that the protrusion on the side of the pulley housing is positioned
toward the outside of the frame.
4Release the elevator belt from the pulley assembly by pushing downward on
the pulley until the pulley shaft falls free. Note that the flattened end of the
pulley shaft is positioned toward the outside of the frame.
To Reinstall:
1Make sure that the locating tabs in the pulley halves fit exactly into their
mating notches. When properly assembled, the pulley halves will not rotate
relative to each other.
2Make sure that the pulley housings are positioned with the shaft protrusion
toward the outside of the frame.
3Make sure to reconnect the lower tension springs.
6-90 Removal and Replacement