HP BMD00022 manual Rmon alarm configuration, Command /cfg/rmon/alarm, Oid 1-127 characters

Models: BMD00022

1 228
Download 228 pages 32.29 Kb
Page 201
Image 201

RMON alarm configuration

Command: /cfg/rmon/alarm <1-65535>

[RMON Alarm 1 Menu]

oid

- Set MIB oid datasource to monitor

intrval

- Set alarm interval

sample

- Set sample type

almtype

- Set startup alarm type

rlimit

- Set rising threshold

flimit

- Set falling threshold

revtidx - Set event index to fire

on rising threshold crossing

fevtidx

- Set event index to fire

on falling threshold crossing

owner

- Set owner for the alarm

 

delete

-

Delete this alarm and restore defaults

cur

-

Display current alarm configuration

The Alarm RMON group can track rising or falling values for a MIB object. The MIB object must be a counter, gauge, integer, or time interval. Each alarm index must correspond to an event index that triggers once the alarm threshold is crossed.

The following table describes the RMON Alarm Menu options.

Table 185 RMON Alarm Menu options

Command

Description

 

 

oid <1-127 characters>

Configures an alarm MIB Object Identifier.

 

The alarm OID can have a maximum of 127 characters.

 

 

intrval <1-65535>

Configures the time interval over which data is sampled and

 

compared with the rising and falling thresholds.

 

The range is from 1 to 65535 seconds. The default is 1800

 

seconds.

 

 

sample absdelta

Configures the method of sampling the selected variable and

 

calculating the value to be compared against the thresholds,

 

as follows:

 

abs—absolute value, the value of the selected variable is

 

compared directly with the thresholds at the end of the

 

sampling interval.

 

delta—delta value, the value of the selected variable at

 

the last sample is subtracted from the current value, and

 

the difference compared with the thresholds.

 

 

almtype risingfallingeither

Configures the alarm type as rising, falling, or either (rising

 

or falling).

 

 

rlimit <-2147483647 to 2147483647>

Configures the rising threshold for the sampled statistic.

 

When the current sampled value is greater than or equal to

 

this threshold, and the value at the last sampling interval was

 

less than this threshold, a single event is generated.

 

 

flimit <-2147483647 to 2147483647>

Configures the falling threshold for the sampled statistic.

 

When the current sampled value is less than or equal to this

 

threshold, and the value at the last sampling interval was

 

greater than this threshold, a single event is generated.

 

 

Configuration Menu 201