HP BMD00022 manual Rmon alarm information, Command /info/rmon/alarm

Models: BMD00022

1 228
Download 228 pages 32.29 Kb
Page 67
Image 67

RMON alarm information

Command: /info/rmon/alarm

RMON Alarm group configuration:

 

 

 

 

Index

Interval

Type

rLimit

fLimit

rEvtIdx

fEvtIdx

last value

-----

--------

----

--------

--------

-------

-------

----------

1

30

abs

10

0

1

0

0

2

900

abs

0

10

0

2

0

3

300

abs

10

20

0

0

0

4

1800

abs

10

0

1

0

0

5

1800

abs

10

0

1

0

0

8

1800

abs

10

0

1

0

56344540

10

1800

abs

10

0

1

0

0

11

1800

abs

10

0

1

0

0

15

1800

abs

10

0

1

0

0

18

1800

abs

10

0

1

0

0

100

1800

abs

10

0

1

0

0

Index

 

OID

 

 

 

 

 

-----

------------------------------

 

 

 

1

1.3.6.1.2.1.2.2.1.10.257

 

 

 

2

1.3.6.1.2.1.2.2.1.11.258

 

 

 

3

1.3.6.1.2.1.2.2.1.12.259

 

 

 

4

1.3.6.1.2.1.2.2.1.13.260

 

 

 

5

1.3.6.1.2.1.2.2.1.14.261

 

 

 

8

1.3.6.1.2.1.2.2.1.10.271

 

 

 

10

1.3.6.1.2.1.2.2.1.15.262

 

 

 

11

1.3.6.1.2.1.2.2.1.16.263

 

 

 

15

1.3.6.1.2.1.2.2.1.19.266

 

 

 

18

1.3.6.1.2.1.2.2.1.10.270

 

 

 

100

1.3.6.1.2.1.2.2.1.17.264

 

 

 

The following table describes the RMON Alarm Information parameters.

Table 42 RMON Alarm Information Menu

Field

Description

 

 

Index

Displays the index number that identifies each alarm instance.

 

 

Interval

Displays the time interval over which data is sampled and compared with the rising

 

and falling thresholds.

 

 

Type

Displays the method of sampling the selected variable and calculating the value to be

 

compared against the thresholds, as follows:

 

abs—absolute value, the value of the selected variable is compared directly with

 

the thresholds at the end of the sampling interval.

 

delta—delta value, the value of the selected variable at the last sample is

 

subtracted from the current value, and the difference compared with the thresholds.

 

 

rLimit

Displays the rising threshold for the sampled statistic.

 

 

fLimit

Displays the falling threshold for the sampled statistic.

 

 

rEvtIdx

Displays the rising alarm event index that is triggered when a rising threshold is

 

crossed.

 

 

fEvtIdx

Displays the falling alarm event index that is triggered when a falling threshold is

 

crossed.

 

 

 

Information Menu 67