Power

Table 6: Transmit status (TxCode) messages and corrective actions

21

The transmitter is disabled

This condition occurs when the transmitter fails a transmit pointing test. This

 

because a transmit pointing

indicates that the transmitter did not meet the minimum specifications required.

 

test failed

This is likely due to an antenna installation problem. The antenna installer needs

 

 

to fine-point the antenna. The transmitter will not transmit until the transmit

 

 

pointing test passes.

 

 

 

22

The transmitter is disabled

This condition occurs when the transmitter is required to perform a periodic

 

pending a transmit pointing

background transmit pointing test, but has not been able to perform the test

 

test

within the time window required. The transmitter is expected to be in this

 

 

condition for no more than two minutes at random periodic intervals. This

 

 

condition can also occur after the transmitter is first powered on after it has been

 

 

powered off for more than a day. If the unit remains in this condition for more

 

 

than two minutes, then the automated transmit pointing components in the NOC

 

 

are likely experiencing problems. This condition should clear in a few minutes.

 

 

 

23

The transmitter is disabled

This condition occurs when the transmitter cannot perform the transmit pointing

 

because a transmit pointing

test when initially installed or when the transmitter is required to range. The

 

test cannot be performed

condition indicates that the NOC components needed to perform the transmit

 

 

pointing test are not operational.

 

 

 

 

Ethernet card

 

AC power

 

cord

Receive

 

modem

 

Transmit

 

modem

Power

 

supply

 

DC power

 

cord

Gateway

 

 

Ethernet cables

T0091013

 

Figure 36: DW4020 connections

Chapter 3 • The User Interface 1031484-0001 Revision 2

41

Page 53
Image 53
Hughes manual Transmit status TxCode messages and corrective actions, DW4020 connections, Power, supply