Figure 90. Available System Monitors

Figure 90 may differ slightly from what will be displayed in your window, depending on which devices you have installed. You can select one or more monitors. For example, you can select monitors for CPU and the C drive utilization, as per Figure 91.

Figure 91. Displaying Monitors

For a discussion on what these objects mean and how they can be used, refer to Chapter 8, ªMonitoring and Performance Tuningº on page131.

6.7 Hints and Tips

We didnt experience any major problems during the installation and configuration of this product. However, the following hints might be of interest to you:

1.After you have installed TME 10 NetFinity, make sure you reboot your server before starting it. Not doing so may produce unpredictable results.

2.Make sure that the network drivers have been installed before installing TME 10 NetFinity; otherwise, you will not be able to define the appropriate network connection during the installation process and you will have to do it later.

3.Set the option Force Remote Logon in the Driver Configuration Options menu. This will ensure only authorized people can access other workstations.

4.Dont forget to define the security service for each workstation. You will find a detailed description on how to do this in Chapter 2 of Systems Management from an NT Server Point of View, SG24-4723.

5.It might also be useful to define Show Execution Alerts within the Network Driver Configuration Options menu. This enables your users to monitor the

Chapter 6. TME 10 NetFinity Overview 117