Event Code Tables A-33
Event Code Tables
Event Code: 512
Message: Optical transceiver nonfatal error.
Severity: Minor.
Explanation: Switch firmware detected an optical transceiver non-fatal error.
Action: Replace the failed transceiver with a functional transceiver of the same type.
Event Data: Byte 0 = port num ber.
Byte 1 = engineering reason code.
Byte 2 = optic type.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 - 11 = optic serial number.
Distribution: Product Management Server Host
EFCM Basic
Event Log System
Error LED Event Log E-Mail Call-Home Sense Info Link Incident
Log
Event Code: 513
Message: Optical transceiver hot-removal completed.
Severity: Informational.
Explanation: An optical transceiver was removed while the switch was powered on and ope rational.
Action: No action required.
Event Data: Byte 0 = port num ber.
Byte 2 = optic type.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 - 11 = optic serial number.
Distribution: Product Management Server Host
EFCM Basic
Event Log System
Error LED Event Log E-Mail Call-Home Sense Info Link Incident
Log