
Maintenance Analysis Procedures 3-19
Maintenence Analysis Procedures
4
A connection is not allowed because of a conf l ict with the configured
port type. An expansion port ( E_Port) is cabled to a Fibre Channel
device or a fabric port (F_Port) is cabled to a dire ctor or fabric switch.
a. Select Ports and Basic Info from the Configure menu at any
view. The Basic Information View displays.
b. If necessary, use t h e vertical scroll bar to d i splay the information
row for the port indicating an invalid attachm ent.
c. Select (click) the Type field an d configure the port as follows:
• Select fabric port (F_Port) if the port is cabled to a device.
• Select expansion port (E_Port) if t he po rt is cabled to a
director or switch (ISL).
d. Click OK or Activate.
05 Loopback plug connected. Go to step 6.
06 N-Port connection not allowed. Go to step 4.
07 Non-McDATA switch at other end. Go to step 5.
08 E_Port capability disabled. Go to step 7.
0A Unauthorized port binding WWN. Go to step 2.
0B Unresponsive node. Go to step 8.
0C ESA security mismatch. Go to step 10.
0D Fabric binding mismatch. Go to step 11.
0E Authorization failure reject. Go to step 8.
0F Unauthorized switch binding WWN. Go to step 10.
10 Authentication failure Go to step 12.
11 Fabric mode mismatch. Go to step 5.
Table 3-9 Invalid Attachment Reasons and Ac tions (Continued)
Byte 4 Invalid Attachment Reason Action