3-12 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
Maintenence Analysis Procedures
2
Ensure the product is connected to facility power. Inspect the product
for indications of being powered on, such as:
An illuminated PWR LED (green) or ERR LED (amber).
Illuminated LEDs adjacent t o F i br e Channel ports.
Audio emanations and airflow from cooli n g fans.
Is the product powered on?
YES NO
A power distribution problem is indica te d. Go to MAP 0100:
Power Distribution Analysi s. Exit MAP.
3
A product-to-PC link problem (Internet too busy or IP addr ess typed
incorrectly) or an Ethernet port failure is in di c ated.
a. Wait approximately five minutes, then attempt to login to the
product.
b. At the Netsite field (Netscape Navigator) or Address field
(Internet Explorer), type http://xxx.xxx.xxx.xxx, where
xxx.xxx.xxx.xxx is the product IP address obtained in MAP
0000: Start MAP. The Username and Password Required dialog
box appears.
c. Type the user name and password obtained in MAP 00 00 : Start
MAP and click OK. If the EFCM Basic Edition interface does not
open, wait five minutes and perform this step again.
Is the EFCM Basic Edition interface operatio nal?
NO YES
The Internet connection is restored. Ex it MAP.
4
The IP address defining the product to the in te rface is incorrect or
unknown. An asynchronous RS-232 modem ca ble and maintenance
terminal (desktop or notebook PC) with a Wind ows-based operating
system and RS-232 serial communication software (such as
ProComm Plus or HyperTerminal) are required. To determine the IP
address: