A-40 McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
Event Code Tables
Thermal Sensor Events (800 through 899)Event Code: 810
Message: High temperature warning (CTP card thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with the CTP card indicates the warm tempera ture threshold was reached or
exceeded.
Action: Perform a data collection and return the CD to support personnel. Perform a switch reset. If the problem persists,
replace the switch.
Event Data: No suppleme ntary data included.
Distribution: Product Management Server Host
EFCM Basic
Event Log System
Error LED Event Log E-Mail Call-Home Sense Info Link Incident
Log
✔✔ ✔
Event Code: 811
Message: Critically hot temperature warning (CTP card thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with the CTP card indicates the hot temperatu re threshold was reached or
exceeded.
Action: Perform a data collection and return the CD to support personnel. Perform a switch reset. If the problem persists,
replace the switch.
Event Data: No suppleme ntary data included.
Distribution: Product Management Server Host
EFCM Basic
Event Log System
Error LED Event Log E-Mail Call-Home Sense Info Link Incident
Log
✔✔ ✔