Maintenance Analysis Procedures 3-31
Maintenence Analysis Procedures
9
An E_Port segmented because two fabric elem en ts had duplicate
domain IDs.
a. Determine the desired domain ID (1 through 31 inclusive) for
each product.
b. Inform the customer both products will be set offline. Ensure the
system administrator quiesces Fibre Ch annel frame traffic and
sets attached devices offline.
c. Set both pro d u cts offline. Refer to Set Online State.
d. Select Switch and Parameters from the Configure menu at any
view. The Parameters View displays.
e. Type the customer-determined preferred domain ID value, then
click OK or Activate.
f. Repeat steps d and e at the second product (attached to the
segmented E_Port). Use a different preferr ed d omain ID value.
g. Set both products online. Refer to Set Online State.
Was the maintenance action successful?
NO YES
The fabric, ISL, and product are operationa l . Exit MAP.
Contact the next level of support. Exit MAP.
10
An E_Port segmented because two produ cts had incompatible zoning
configurations. An identical zone name is recognized in the active
zone set for both products, but the zones contain di ff ere nt members.
a. Determine the desired zone name ch ange for one of the affected
products. Zone names must conform to the foll ow ing rules:
The name must be 64 characters or fewer in length.
The first character must be a letter (a through z), uppe r or
lower case.
Ot he r characters must be alphanumeric (a through z
or 0 through 9), dollar sign ($), hyphen (-), caret (^), or
underscore (_).