Oki 6100E+ manual Hardware Error Messages

Models: 6100E+

1 254
Download 254 pages 6.16 Kb
Page 130
Image 130

Section 4 - Appendix A - Troubleshooting

OkiNet for TCP/IP - Winsock Errors

If you see an error before OkiNet for TCP/IP appears on the screen, try setting a host name in the hosts file in the Windows directory (check the documentation for your Windows TCP/IP stack).

If you have difficulty seeing a particular OkiLAN 6100e+, try moving the device onto the same subnet as the computer running the utility.

If OkiNet for TCP/IP gives you the Winsock error: Could not bind to socket, use the Special Options dialog under the File menu to change the Discovery UDP Port to a different port number.

Hardware Error Messages

ST: Cable not connected

Self-test has determined that the network cable is not connected.

Check the cable connection to the OkiLAN 6100e+.

Move the OkiLAN 6100e+ to another known working node.

If you find the cable is connected and you are still receiving this message or any other “ST:” error message, power cycle the OkiLAN 6100e+. If the error continues, call Okidata Customer Support at 1-800-OKIDATA (1-800-654-3282).

System CRC Failed

The OkiLAN 6100e+ has failed.

Power cycle the OkiLAN 6100e+ once. If the error continues, call Okidata Customer Support at 1-800-OKIDATA (1-800-654-3282).

IV - 52

OKI OkiLAN 6100e+ User’s Guide

Page 130