Omron CS1W-ETN21 operation manual Send Mail Status 1, 2 Ethernet Unit to CPU Unit, Bits Status

Models: CS1W-ETN21

1 285
Download 285 pages 16.7 Kb
Page 112
Image 112

DM Area Allocations

Section 4-2

The meanings of the items shown in the above diagram are explained on the following pages. For details regarding the related communications services shown in the diagram, refer to the indicated sections.

Send Mail Status 1, 2 (Ethernet Unit to CPU Unit)

Send Mail Status 1

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

m

Status of Send Condition Setting 1

Status of Send Condition Setting 2

Status of Send Condition Setting 3

Status of Send Condition Setting 4

Send Mail Status 2

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

m+17

Status of Send Condition Setting 5

Status of Send Condition Setting 6

Status of Send Condition Setting 7

Status of Send Condition Setting 8

The transmission status of user mail, periodic mail, and error log mail are stored in this word as shown in the following table.

 

Bits

 

Status

 

 

 

 

02

01

00

 

 

 

 

 

06

05

04

 

 

 

 

 

10

09

08

 

 

 

 

 

14

13

12

 

 

 

 

 

OFF

OFF

OFF

Mail is either waiting to be sent or can be sent using the Mail

 

 

 

Send Switch. No mail is being sent.

 

 

 

 

OFF

OFF

ON

Mail is being sent.

 

 

 

 

OFF

ON

OFF

Mail is either waiting to be sent or can be sent using the Mail

 

 

 

Send Switch. The previous mail transmission was completed

 

 

 

normally.

 

 

 

 

ON

ON

OFF

Mail is either waiting to be sent or can be sent using the Mail

 

 

 

Send Switch. An error occurred in the previous mail transmis-

 

 

 

sion.

 

 

 

 

ON

ON

ON

Mail cannot be sent (system setting error).

 

 

 

 

While mail is being sent, the transmission status of the three bits each for send condition settings 1 to 8, i.e., bits 02, 01, and 00; bits 06, 05, and 04; or bits 10, 09, an 08 are 0, 0, and 1 respectively. After the transmission has been completed normally, they become 0, 1, and 0. If the transmission is ended with an error, they become 1, 1, and 0.

Check this transmission status in the ladder program as required.

87