Omron CS1W-ETN21 operation manual Read/Write Bits User Settings, Bits Name Description Settings

Models: CS1W-ETN21

1 285
Download 285 pages 16.7 Kb
Page 116
Image 116

Auxiliary Area Data

 

Section 4-3

 

 

 

 

 

Word(s)

Bit(s)

Name

Function

Settings

 

 

 

 

 

A417

A41700 to

CPU Bus Unit Error,

When an error occurs in a data exchange between

0: No error

 

A41715

Unit Number Flags

the CPU Unit and a CPU Bus Unit, the CPU Bus

1: Error

 

 

 

Unit Error Flag (A40207) and the corresponding flag

 

 

 

 

 

 

 

in A417 are turned ON. Bits 00 to 15 correspond to

 

 

 

 

unit numbers 0 to F.

 

 

 

 

The ERR/ALM indicator on the front of the CPU Unit

 

 

 

 

will flash, but CPU operation will continue.

 

 

 

 

 

 

A427

A42700 to

CPU Bus Unit Set-

When a CPU Bus Unit Setting Error occurs, A40203

0: No setting error

 

A42715

ting Error, Unit

and the corresponding flag in A27 are turned ON.

1: Setting error

 

 

Number Flags

Bits 00 to 15 correspond to unit numbers 0 to F.

 

 

 

 

 

 

The ERR/ALM indicator on the front of the CPU Unit

 

 

 

 

will flash, but CPU operation will continue.

 

Read/Write Bits (User Settings)

 

 

 

 

 

 

 

Word

Bits

Name

Description

Settings

 

 

 

 

 

A501

A50100 to

CPU Bus Unit

Bits A50100 through A50115 can be turned ON to

OFF to ON:

 

A50115

Restart Bits

reset CPU Bus Units number #0 through #15,

Unit restarted.

 

 

 

respectively.

Automatically turned

 

 

 

The Restart Bits are turned OFF automatically when

 

 

 

OFF by system after

 

 

 

restarting is completed.

restart processing

 

 

 

The CPU Bus Unit Initializing Flags (A30200 to

has been completed.

 

 

 

 

 

 

 

A30215) will turn ON when initialization of the Units

 

 

 

 

begins and turn OFF when it is completed.

 

 

 

 

 

 

91

Page 116
Image 116
Omron CS1W-ETN21 operation manual Read/Write Bits User Settings, Bits Name Description Settings