Omron CS1W-ETN21 operation manual Writing Programs

Models: CS1W-ETN21

1 285
Download 285 pages 16.7 Kb
Page 166
Image 166

Communicating between OMRON PLCs

Section 6-6

 

 

 

 

 

 

Usage

 

Command

Name

Function

 

 

 

code

 

 

 

 

 

 

 

 

 

MR

 

SR

 

 

 

 

 

 

 

 

 

File memory

22

 

 

01

FILE NAME READ

Reads file memory data.

 

 

 

 

 

 

 

 

22

 

 

02

SINGLE FILE READ

Reads a specified length of file data

 

 

 

 

 

 

from a specified position within a single

 

 

 

 

 

 

file.

 

 

 

 

 

 

 

 

22

 

 

03

SINGLE FILE WRITE

Writes a specified length of file data

 

 

 

 

 

 

from a specified position within a single

 

 

 

 

 

 

file.

 

 

 

 

 

 

 

 

22

 

 

04

FILE MEMORY FORMAT

Formats (initializes) the file memory.

 

 

 

 

 

 

 

 

22

 

 

05

FILE DELETE

Deletes specified files stored in the file

 

 

 

 

 

 

memory.

 

 

 

 

 

 

 

 

22

 

 

07

FILE COPY

Copies files from one file memory to

 

 

 

 

 

 

another file memory in the same sys-

 

 

 

 

 

 

tem.

 

 

 

 

 

 

 

 

22

 

 

08

FILE NAME CHANGE

Changes a file name.

 

 

 

 

 

 

 

 

22

 

 

0A

MEMORY AREA–FILE TRANSFER

Transfers or compares data between the

 

 

 

 

 

 

I/O memory area and the file memory.

 

 

 

 

 

 

 

 

22

 

 

0B

PARAMETER AREA–FILE TRANSFER

Transfers or compares data between the

 

 

 

 

 

 

parameter area and the file memory.

 

 

 

 

 

 

 

 

22

 

 

0C

PROGRAM AREA–FILE TRANSFER

Transfers or compares data between the

 

 

 

 

 

 

UM (User Memory) area and the file

 

 

 

 

 

 

memory.

 

 

 

 

 

 

 

 

22

 

 

15

CREATE/DELETE DIRECTORY

Creates or deletes a directory.

 

 

 

 

 

 

 

Debugging

23

 

 

01

FORCED SET/RESET

Force-sets or force-resets bits, or

 

 

 

 

 

 

releases force-set status.

 

 

 

 

 

 

 

 

23

 

 

02

FORCED SET/RESET CANCEL

Cancels all bits that have been force-set

 

 

 

 

 

 

or force-reset.

 

 

 

 

 

 

 

6-6-4 Writing Programs

Programs incorporating the SEND(090), RECV(098), and CMND(490) instructions are generally created using the Communications Port Enabled Flag and the Communications Port Error Flag as input conditions. CS/CJ- series CPU Units have eight communications ports. Only one instruction can be executed at any given port at one time, however, so the program must not overlap the use of any of the ports. A program example is provided below.

Communications port

Ethernet Unit

CPU Unit

 

 

Instruction 1

 

Instruction 2

 

Instruction 3

 

Instruction 4

 

Instruction 5

 

Instruction 6

 

Instruction 7

 

Instruction 8

There are eight communications ports, so up to eight communications instructions can be executed at a time. The number of messages that can be sent or received with a single CPU Bus Unit ser-vice, though, is not more than two each for the CPU Unit to the Ethernet Unit and for the Ethernet Unit to the CPU Unit.

141

Page 166
Image 166
Omron CS1W-ETN21 operation manual Writing Programs