Ethernet Unit Function Guide

Section 1-1

 

Mail software

Receiving e-mail

E-mail

IP router

Firewall

Internet

(Server room)

DNS server

POP3 server

SMTP server

SNTP server Ethernet

Intranet

(Office floor)

Mail software

Receiving e-mail

Ethernet Router

Router

 

 

(Production line)

Ethernet

 

 

Ethernet Unit

Sending

 

e-mail

 

(5) Monitoring PLC changes

PLC's I/O memory data

and sending equipment

status to the operator by

sent as attached file

e-mail

 

Reference

SECTION 2 Mail Send Function in the Operation Manual Construction of

 

Applications

Receiving E-mail (Data and Files) at the PLC

Operation

Use the mail receive function.

When the mail receive function is used, the PLC can be accessed through a mail address, enabling remote applications via the Internet to be constructed relatively easily. With the mail receive function, any of the following remote commands can be specified as e-mail subjects.

• FileWrite (File Write)

• ChangeMode (Operating Mode

• FileRead (File Read)

Change)

 

• FileDelete (File Delete)

• ErrorLogRead (Error Log Read)

 

• FileList (File List Read)

• ErrorLogClear (Error Log Clear)

 

• UMBackup (User Memory

• MailLogRead (Mail Log Read)

 

Backup)

• MailLogClear (Mail Log Clear)

• PARAMBackup (Parameter Area

• Test (Mail Test)

Backup)

• FinsSend (FINS Command

 

• IOMWrite (I/O Memory Write)

Send)

• IOMRead (I/O Memory Read)

 

To use the mail receive function, there must be a separate POP3 server on the network. Aside from the IP address, the host name used for DNS service can be specified for the POP3 server.

6

Page 31
Image 31
Omron CS1W-ETN21 operation manual Receiving E-mail Data and Files at the PLC, Operation Use the mail receive function