Omron CS1W-ETN21 operation manual Auto Adjust Time, Sntp Server Setup

Models: CS1W-ETN21

1 285
Download 285 pages 16.7 Kb
Page 99
Image 99

Auto Adjust Time

Section 3-9

For details, refer to SECTION 3 Mail Receive Function in the Operation Man- ual Construction of Applications.

3-9 Auto Adjust Time

SNTP Server Setup

Item

Contents

Default

 

 

 

Get the time

If this option is selected, the CPU Unit's clock is set to

Not

information from

the time at the SNTP server's clock.

checked

the SNTP

The clock can be changed only for the CPU Unit to

 

server

 

which the Ethernet Unit is mounted.

 

 

 

 

 

 

Auto Adjust

Set the time at which the SNTP server is to be

0:0:0

Time

accessed to synchronize the clocks.

 

 

When the time that is set here arrives, the SNTP

 

 

server is accessed and the CPU Unit clock is

 

 

adjusted to match the SNTP server clock.

 

 

 

 

Server specifi-

Select whether the SNTP server used for automatic

IP Address

cation type

clock adjustment is to be specified by IP address or

 

 

by host domain name (i.e., by host name).

 

 

 

 

IP Address

Set the IP address for the SNTP server that is to be

0.0.0.0

 

used for automatic clock adjustment.

 

 

This setting is enabled only when server specification

 

 

by IP address has been selected.

 

 

 

 

Host name

Set the host domain name (i.e., the host name) for

None

 

the SNTP server that is to be used for automatic

 

 

clock adjustment.

 

 

This setting is enabled only when server specification

 

 

by host name has been selected.

 

 

 

 

Port No.

Set the port number for connecting to the SNTP

0

 

server that is to be used for automatic clock adjust-

(Number

 

ment. This setting does not normally need to be

123 is

 

changed.

used.)

74