User’s Manual of
The maximum disatance VCT can function is 120 meters.
Examples
The following example results in a report on the cable attached to port e3.
Console# test
Cable is open at 100 meters
The following example results in a failure to report on the cable attached to port e4.
Console# test
Can’t perform the test on fiber ports
5.14.2 showThe show
ports.
Syntax
show
interface — A valid Ethernet port.
Default Configuration
This command has no default configuration.
Command Mode
Privileged EXEC mode
User Guidelines
There are no user guidelines for this command.
Example
The following example displays the last TDR (Time Domain Reflectometry) tests on all ports.
Console# show |
|
| |
Port | Result | Length | Date |
|
| [meters] |
|
e1 | OK |
|
|
e2 | Short | 50 | 13:32:00 23 July 2003 |
e3 | Test has not been preformed |
|
|
e4 | Short | 128 | 13:32:00 23 July 2003 |
e5 | Fiber | - | - |
|
|
|
|
- 248 –