User’s Manual of WGSD-1022/WGSD-8000

The maximum disatance VCT can function is 120 meters.

Examples

The following example results in a report on the cable attached to port e3.

Console# test copper-port tdr e3

Cable is open at 100 meters

The following example results in a failure to report on the cable attached to port e4.

Console# test copper-port tdr e4

Can’t perform the test on fiber ports

5.14.2 show copper-ports tdr

The show copper-ports tdr privileged EXEC command display the last TDR (Time Domain Reflectometry) tests on specified

ports.

Syntax

show copper-ports tdr [interface]

ƒinterface — A valid Ethernet port.

Default Configuration

This command has no default configuration.

Command Mode

Privileged EXEC mode

User Guidelines

There are no user guidelines for this command.

Example

The following example displays the last TDR (Time Domain Reflectometry) tests on all ports.

Console# show copper-ports tdr

 

 

Port

Result

Length

Date

 

 

[meters]

 

-------

-----------

--------------

---------

e1

OK

 

 

e2

Short

50

13:32:00 23 July 2003

e3

Test has not been preformed

 

 

e4

Short

128

13:32:00 23 July 2003

e5

Fiber

-

-

 

 

 

 

- 248 –