User’s Manual of
startup direction — The alarm that may be sent when this entry is first set to valid. If the first sample (after this entry becomes valid) is greater than or equal to the rthreshold, and direction is equal to rising or
owner name — Enter a name that specifies who configured this alarm. If unspecified, the name is an empty string.
Default Configuration
The following parameters have the following default values: type type — If unspecified, the type is absolute.
startup direction — If unspecified, the startup direction is
Command Mode
Global Configuration mode
User Guidelines
There are no user guidelines for this command.
Example
The following example configures the following alarm conditions:
Alarm index — 1000
Variable identifier — abc
Sample interval — 360000 seconds
Rising threshold — 1000000
Falling threshold — 1000000
Rising threshold event index — 10
Falling threshold event index — 20
Console (config)# rmon alarm 1000 abc 360000 1000000 1000000 10 20
5.19.6 show rmonThe show rmon
Syntax
show rmon
Default Configuration
This command has no default configuration.
- 281 –