User’s Manual of WGSD-1022/WGSD-8000

Default Configuration

This command has no default configuration.

Command Mode

Privileged EXEC mode

User Guidelines

To test optical transceivers ensure a fiber link is present.

Examples

The following example displays the optical transceiver diagnostics.

console# show fiber-ports optical-transceiver

Port

Temp

Voltage

Current

Output

Input

LOS

 

 

 

Power

Power

Power

 

------

--------

------------

------------

-----------

----------

---------

g1

W

OK

E

OK

OK

OK

g2

OK

OK

OK

OK

OK

OK

e3

Copper

 

 

 

 

 

Temp – Internally measured transceiver temperature.

Voltage - Internally measured supply voltage.

Current – Measured TX bias current.

Output Power – Measured TX output power.

Input Power – Measured RX received power.

Tx Fault – Transmitter fault

LOS – Loss of signal

Data ready – Indicates transceiver has achieved power up and data is ready.

N/A - Not Available, N/S - Not Supported, W - Warning, E - Error

The following example displays detailed optical transceiver diagnostics

console# show fiber-ports transceiver detailed

 

 

 

Port

Temp

Voltage

Current

Output

Input

LOS

 

[C]

[Volt]

[mA]

Power

Power

 

 

 

 

 

[mWatt]

[mWatt]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 250 –