GENERAL PROGRAMS
KEY OPERATOR PROGRAMS |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
OPERATION SETTINGS |
|
|
| OK | |||
|
|
|
|
|
|
| |
|
|
|
|
|
|
| 1/3 |
| AUTO CLEAR SETTING |
|
| 60sec |
| ||
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| MESSAGE TIME SETTING |
|
| 6sec |
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| KEYS TOUCH SOUND |
|
|
|
|
|
The "OPERATION SETTINGS" are related to basic operation of the machine and consist of the following programs:
●DISABLING OF CLOCK ADJUSTMENT
AUTO CLEAR SETTING
If no action is taken for a certain length of time when viewing information on finished jobs, jobs in progress, or stored jobs, the auto clear function activates and returns the display to the initial screen of copy mode or the job status screen. AUTO CLEAR SETTING is used to set the amount of time that must elapse for the auto clear function to activate. The time can be set from 10 seconds to 240 seconds in increments of 10 seconds, or the auto clear function can be disabled. (This setting only operates in copy mode and network scanner mode.)
The factory default setting is "60" (sec.).
MESSAGE TIME SETTING
This program is used to set the length of time that messages appear in the display (this applies to messages that appear for a certain length of time and then automatically disappear.)
The time can be set to as long as 12 seconds in increments of one second.
The factory default setting is "6" (sec.).
KEYS TOUCH SOUND
This program is used to select whether or not a beep is sounded when a key is touched, and if sounded, what type of beep.
The program is also use to select whether or not a special key touch beep is sounded at the initial point of a setting.
The factory default settings are as follows:
•KEYS TOUCH SOUND: Short
•KEYS TOUCH SOUND AT INITIAL POINT: Disabled
KEY OPERATOR PROGRAMS
KEYS TOUCH SOUND | OK | ||
|
|
| |
| KEYS TOUCH SOUND |
|
|
KEYS TOUCH SOUND AT INITIAL POINT
key .... Touch this key to select a short beep
volume. A single short beep indicates a valid key, and a double short beep indicates an invalid key.
key .... Touch this key to select a long beep
volume. A single long beep indicates a valid key, and a double long beep indicates an invalid key.
key .... Touch this key to disable key touch beeps.
Select the [KEYS TOUCH SOUND AT INITIAL POINT] checkbox to have three long beeps sound (when the beep volume is set to long) or three short beeps sound (when the beep volume is set to short) when the initial point of a setting is reached while selecting basic settings. The initial point settings are as follows:
Mode | Initial point (set from initial screen) |
Copy mode | Ratio: 100% |
| Exposure: 3 |
|
|
Fax mode | Exposure: 3 |
|
|
Network scanner | Exposure setting: 3 |
mode |
|
|
|
TOUCH KEY OPERATION SETTING
These programs are used to set the length of time that must elapse until a setting is entered after a key is touched, and to disable key repeat.
The setting entry time can be set from 0.0 seconds to 2.0 seconds in increments of 0.5 seconds.
When [DISABLE AUTO KEY REPEAT] is enabled, only one touch is registered if key is touched continuously. The factory default settings are as follows:
•Time to entry: 0.0 (sec.)
•DISABLE AUTO KEY REPEAT: Disabled
DISABLE INTERRUPT PRINT JOB
(When the printer function is enabled)
Enable this program if you wish to prevent pausing of printing for interrupt copy jobs.
This program is initially disabled (factory default setting).