Two Port 10/100 Managed Ethernet Switch with
Datasheet
controller drives all the address bits as requested regardless of the actual size of the EEPROM. The supported size ranges for I2C operation are shown in Table 10.2.
Table 10.2 I2C EEPROM Size Ranges
eeprom_size_strap[0] | # OF ADDRESS BYTES | EEPROM SIZE | EEPROM TYPES |
|
|
|
|
0 | 1 (Note 10.1) | 16 x 8 through 2048 x 8 | 24xx00, 24xx01, 24xx02, |
|
|
| 24xx04, 24xx08, 24xx16 |
|
|
|
|
1 | 2 | 4096 x 8 through 65536 x 8 | 24xx32, 24xx64, 24xx128, |
|
|
| 24xx256, 24xx512 |
|
|
|
|
Note 10.1 Bits in the control byte are used as the upper address bits.
The I2C master interface runs at the
I2C is a
The following bus states exist:
Idle: Both EE_SDA and EE_SCL are high when the bus is idle.
Start & Stop Conditions: A start condition is defined as a high to low transition on the EE_ SDA line while EE_ SCL is high. A stop condition is defined as a low to high transition on the EE_SDA line while EE_SCL is high. The bus is considered to be busy following a start condition and is considered free 4.7uS/1.3uS (for 100KHz and 400KHz operation, respectively) following a stop condition. The bus stays busy following a repeated start condition (instead of a stop condition). Starts and repeated starts are otherwise functionally equivalent.
Data Valid: Data is valid, following the start condition, when EE_SDA is stable while EE_SCL is high. Data can only be changed while the clock is low. There is one valid bit per clock pulse. Every byte must be 8 bits long and is transmitted msb first.
Acknowledge: Each byte of data is followed by an acknowledge bit. The master generates a ninth clock pulse for the acknowledge bit. The transmitter releases EE_SDA (high). The receiver drives EE_SDA low so that it remains valid during the high period of the clock, taking into account the setup and hold times. The receiver may be the master or the slave depending on the direction of the data. Typically the receiver acknowledges each byte. If the master is the receiver, it does not generate an acknowledge on the last byte of a transfer. This informs the slave to not drive the next byte of data so that the master may generate a stop or repeated start condition.
SMSC LAN9311/LAN9311i | 141 | Revision 1.4 |
| DATASHEET |
|