Two Port 10/100 Managed Ethernet Switch with 16-Bit Non-PCI CPU Interface

Datasheet

14.2.9.4Power Management Control Register (PMT_CTRL)

Offset:

084h

Size:

32 bits

This read-write register controls the power management features and the PME pin of the LAN9311/LAN9311i. The ready state of the LAN9311/LAN9311i can be determined via the Device Ready (READY) bit of this register. Refer to Section 4.3, "Power Management," on page 46 for additional information.

Note: This register is one of only four registers (the others are HW_CFG, BYTE_TEST, and RESET_CTL) which can be polled while the LAN9311/LAN9311i is in the reset or not ready state (READY bit is cleared).

Note: Either half of this register can be read without the need to read the other half.

BITS

DESCRIPTION

TYPE

DEFAULT

 

 

 

 

31:18

RESERVED

RO

-

 

 

 

 

17

Energy-Detect Status Port 2 (ED_STS2)

R/WC

0b

 

This bit indicates an energy detect event occurred on the Port 2 PHY.

 

 

 

In order to clear this bit, it is required that the event in the PHY be cleared

 

 

 

as well. The event sources are described in Section 4.3, "Power

 

 

 

Management," on page 46.

 

 

 

 

 

 

16

Energy-Detect Status Port 1 (ED_STS1)

R/WC

0b

 

This bit indicates an energy detect event occurred on the Port 1 PHY.

 

 

 

In order to clear this bit, it is required that the event in the PHY be cleared

 

 

 

as well. The event sources are described in Section 4.3, "Power

 

 

 

Management," on page 46.

 

 

 

 

 

 

15

Energy-Detect Enable Port 2 (ED_EN2)

R/W

0b

 

When set, the PME signal (if enabled via the PME_EN bit) will be asserted

 

 

 

in accordance with the PME_IND bit upon an energy-detect event from Port

 

 

 

2. When set, the PME_INT bit in the Interrupt Status Register (INT_STS) will

 

 

 

also be asserted upon an energy-detect event from Port 2, regardless of the

 

 

 

setting of the PME_EN bit.

 

 

 

Note: The EDPWRDOWN bit of the Port x PHY Mode Control/Status

 

 

 

Register (PHY_MODE_CONTROL_STATUS_x) of the Port 2 PHY

 

 

 

must also be set to enable the energy detect feature.

 

 

 

 

 

 

14

Energy-Detect Enable Port 1 (ED_EN1)

R/W

0b

 

When set, the PME signal (if enabled via the PME_EN bit) will be asserted

 

 

 

in accordance with the PME_IND bit upon an energy-detect event from Port

 

 

 

1. When set, the PME_INT bit in the Interrupt Status Register (INT_STS) will

 

 

 

also be asserted upon an energy-detect event from Port 1, regardless of the

 

 

 

setting of the PME_EN bit.

 

 

 

Note: The EDPWRDOWN bit in the Port x PHY Mode Control/Status

 

 

 

Register (PHY_MODE_CONTROL_STATUS_x) of the Port 1 PHY

 

 

 

must also be set to enable the energy detect feature.

 

 

 

 

 

 

13:11

RESERVED

RO

-

 

 

 

 

10

Virtual PHY Reset (VPHY_RST)

R/W

0b

 

Writing a 1 to this bit resets the Virtual PHY. When the Virtual PHY is

SC

 

 

released from reset, this bit is automatically cleared. All writes to this bit are

 

 

 

ignored while this bit is high.

 

 

 

 

 

 

Revision 1.4 (08-19-08)

264

SMSC LAN9311/LAN9311i

 

DATASHEET