Two Port 10/100 Managed Ethernet Switch with
Datasheet
14.5.4.6Buffer Manager Port 0 Drop Count Register (BM_DRP_CNT_SRC_MII)Register #: | 1C05h | Size: | 32 bits |
This register counts the number of packets dropped by the Buffer Manager that were received on Port 0(Host MAC). This count includes packets dropped due to buffer space limits and ingress rate limit discarding (Red and random Yellow dropping).
BITS | DESCRIPTION | TYPE | DEFAULT |
|
|
|
|
31:0 | Dropped Count | RC | 00000000h |
| These bits count the number of dropped packets received on Port 0 and is |
|
|
| cleared when read. |
|
|
| Note: The counter will stop at its maximum value of FFFF_FFFFh. |
|
|
| Minimum rollover time at 100Mbps is approximately 481 hours. |
|
|
|
|
|
|
Revision 1.4 | 418 | SMSC LAN9311/LAN9311i |
| DATASHEET |
|