Two Port 10/100 Managed Ethernet Switch with
Datasheet
14.4.2.11Port x PHY Interrupt Source Flags Register (PHY_INTERRUPT_SOURCE_x)Index (decimal): 29 | Size: | 16 bits |
This
BITS | DESCRIPTION | TYPE | DEFAULT |
|
|
|
|
15:8 | RESERVED | RO | - |
|
|
|
|
7 | INT7 | RO/LH | 0b |
| This interrupt source bit indicates when the ENERGYON bit of the Port x |
|
|
| PHY Mode Control/Status Register (PHY_MODE_CONTROL_STATUS_x) |
|
|
| has been set. |
|
|
| 0: Not source of interrupt |
|
|
| 1: ENERGYON generated |
|
|
|
|
|
|
6 | INT6 | RO/LH | 0b |
| This interrupt source bit indicates |
|
|
| 0: Not source of interrupt |
|
|
| 1: |
|
|
|
|
|
|
5 | INT5 | RO/LH | 0b |
| This interrupt source bit indicates a remote fault has been detected. |
|
|
| 0: Not source of interrupt |
|
|
| 1: Remote fault detected |
|
|
|
|
|
|
4 | INT4 | RO/LH | 0b |
| This interrupt source bit indicates a Link Down (link status negated). |
|
|
| 0: Not source of interrupt |
|
|
| 1: Link Down (link status negated) |
|
|
|
|
|
|
3 | INT3 | RO/LH | 0b |
| This interrupt source bit indicates an |
|
|
| 0: Not source of interrupt |
|
|
| 1: |
|
|
|
|
|
|
2 | INT2 | RO/LH | 0b |
| This interrupt source bit indicates a Parallel Detection fault. |
|
|
| 0: Not source of interrupt |
|
|
| 1: Parallel Detection fault |
|
|
|
|
|
|
1 | INT1 | RO/LH | 0b |
| This interrupt source bit indicates an |
|
|
| 0: Not source of interrupt |
|
|
| 1: |
|
|
|
|
|
|
0 | RESERVED | RO | - |
|
|
|
|
Revision 1.4 | 306 | SMSC LAN9311/LAN9311i |
| DATASHEET |
|