Two Port 10/100 Managed Ethernet Switch with
Datasheet
| Table 4.3 |
| |||||||
|
|
|
|
|
|
|
|
|
|
STRAP NAME |
|
|
|
|
| DESCRIPTION | PIN | ||
|
|
|
|
|
|
|
|
| |
eeprom_type_strap |
|
| EEPROM Type Strap: Configures the EEPROM type. | EEPROM_TYPE | |||||
|
|
| 0 = Microwire Mode |
|
|
|
| ||
|
|
| 1 = I2C Mode |
|
|
|
|
| |
eeprom_size_strap[1:0] |
|
| EEPROM Size Strap [1:0]: Configures the EEPROM size | EEPROM_SIZE_[1:0] | |||||
|
|
| range as specified in Section 10.2, "I2C/Microwire Master |
| |||||
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| |
phy_addr_sel_strap |
|
| PHY Address Select Strap: Configures the default MII | PHY_ADDR_SEL | |||||
|
|
| management address values for the PHYs and Virtual PHY |
| |||||
|
|
| as detailed in Section 7.1.1, "PHY Addressing," on page 82. |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| PHY_ADDR_SEL_STRAP VALUE | VIRTUAL PHY ADDRESS | PORT 1 PHY ADDRESS |
| PORT 2 PHY ADDRESS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0 | 0 | 1 |
| 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 | 1 | 2 |
| 3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4.3Power Management
The LAN9311/LAN9311i Port 1 and Port 2 PHYs and the Host MAC support several power management and wakeup features.
The LAN9311/LAN9311i can be programmed to issue an external wake signal (PME) via several methods, including wake on LAN, wake on link status change (energy detect), and magic packet wakeup. The PME signal is ideal for triggering system
The PME module handles the latching of the Port 1 & 2 PHY
The PME output characteristics can be configured via the PME_TYPE, PME_IND, and PME_POL bits of the Power Management Control Register (PMT_CTRL). These bits allow the PME to be
Revision 1.4 | 46 | SMSC LAN9311/LAN9311i |