Two Port 10/100 Managed Ethernet Switch with 16-Bit Non-PCI CPU Interface

Datasheet

14.5.3.35Switch Engine Port 2 Ingress VLAN Priority Regeneration Table Register (SWE_INGRSS_REGEN_TBL_2)

Register #:

1857h

Size:

32 bits

This register provides the ability to map the received VLAN priority to a regenerated priority. The regenerated priority is used in determining the output priority queue. By default, the regenerated priority is identical to the received priority.

BITS

DESCRIPTION

TYPE

DEFAULT

 

 

 

 

31:24

RESERVED

RO

-

 

 

 

 

23:21

Regen7

R/W

7h

 

These bits specify the regenerated priority for received priority 7.

 

 

 

 

 

 

20:18

Regen6

R/W

6h

 

These bits specify the regenerated priority for received priority 6.

 

 

 

 

 

 

17:15

Regen5

R/W

5h

 

These bits specify the regenerated priority for received priority 5.

 

 

 

 

 

 

14:12

Regen4

R/W

4h

 

These bits specify the regenerated priority for received priority 4.

 

 

 

 

 

 

11:9

Regen3

R/W

3h

 

These bits specify the regenerated priority for received priority 3.

 

 

 

 

 

 

8:6

Regen2

R/W

2h

 

These bits specify the regenerated priority for received priority 2.

 

 

 

 

 

 

5:3

Regen1

R/W

1h

 

These bits specify the regenerated priority for received priority 1.

 

 

 

 

 

 

2:0

Regen0

R/W

0h

 

These bits specify the regenerated priority for received priority 0.

 

 

 

 

 

 

Revision 1.4 (08-19-08)

406

SMSC LAN9311/LAN9311i

 

DATASHEET